307
Critical
A temperature sensor on a controller FRU detected an over-temperature condition that caused the controller
to shut down.
Recommended actions
Check that the storage system's fans are running.
Check that the ambient temperature is not too warm. The enclosure operating range is 41–104° F
(5–40° C).
Check for any obstructions to the airflow.
If none of the above explanations apply, replace the controller FRU that reported the error.
308
Info.
The default host port speed has changed from 4 Gbit/sec to 2 Gbit/sec because the controller module's
HIM has a Broadcom PBC.
Recommended actions
No action required.
309
Info.
Normally when the Management Controller (MC) is started, the IP data is obtained from the midplane FRU
ID SEEPROM where it is persisted. If the system is unable to write it to the SEEPROM the last time it
changed, a flag is set in flash memory. This flag is checked during startup, and if set, this event is logged
and the IP data that is in flash memory is used. The only time that this would not be the correct IP data
would be if the controller module was swapped and then whatever data is on the controller's flash memory
is used.
Recommended actions
No action required.
310
Info.
After a rescan, back-end discovery and initialization of data for at least one EMP (Enclosure Management
Processor) has completed. This event is not logged again when processing completes for other EMPs in the
system.
Recommended actions
No action required.
31 1
Info.
An iSCSI ping operation completed. The event specifies the number of pings that passed and the number
that failed.
Recommended actions
If the ping operation failed, check connectivity between the storage system and the remote host.
312
Info.
This event is used by email messages and SNMP traps when testing notification settings. This event is not
recorded in the event log.
Recommended actions
No action required.
313
Error
The indicated controller module has failed. This event can be ignored for a single-controller configuration.
Recommended actions
Replace the failed controller module. The module's Fault/Service Required LED will be illuminated (not
blinking).
HP P2000 G3 MSA System Event Descriptions Reference Guide