HP P2000 Reference Manual page 10

Msa system event descriptions
Hide thumbs Also See for P2000:

Advertisement

68
Info.
The controller that logged this event is shut down, or both controllers are shut down.
Recommended actions
No action required.
71
Info.
The controller has started or completed failing over.
Recommended actions
No action required.
72
Info.
After failover, recovery has either started or completed.
Recommended actions
No action required.
73
Info.
The two controllers are communicating with each other and cache redundancy is enabled.
Recommended actions
No action required.
74
Info.
The FC loop ID for the indicated vdisk was changed to be consistent with the IDs of other vdisks. This can
occur when disks containing a vdisk are inserted from an enclosure having a different FC loop ID.
This event is also logged by the new owning controller after vdisk ownership is changed.
Recommended actions
No action required.
75
Info.
The indicated volume's LUN has been unassigned because it conflicts with LUNs assigned to other
volumes. This can happen when disks containing data for a mapped volume have been inserted from
another enclosure.
Recommended actions
If you want hosts to access the volume data on the inserted disks, map the volume with a different LUN.
76
Info.
The controller is using default configuration settings. This event occurs on the first power up, and might
occur after a firmware update.
Recommended actions
If you have just performed a firmware update and your system requires special configuration settings,
you must make those configuration changes before your system will operate as before.
77
Info.
The cache was initialized as a result of power up or failover.
Recommended actions
No action required.