Introduction
This guide is for reference by storage administrators to help troubleshoot storage-system issues. It describes
event messages that may be reported during system operation and specifies any actions recommended in
response to an event.
Events and event messages
When an event occurs in a storage system, an event message is recorded in the system's event log
and—depending on the system's event notification settings—may also be sent to users (via email) and
host-based applications (via SNMP or SMI-S).
Each event has a numeric code that identifies the type of event that occurred, and has one of the following
severities:
Critical. A failure occurred that may cause a controller to shut down. Correct the problem immediately.
Error. A failure occurred that may affect data integrity or system stability. Correct the problem as soon
as possible.
Warning. A problem occurred that may affect system stability but not data integrity. Evaluate the
problem and correct it if necessary.
Informational. A configuration or state change occurred, or a problem occurred that the system
corrected. No immediate action is required. In this guide, this severity is abbreviated as "Info."
An event message may specify an associated error code or reason code. Error codes and reason codes
are outside the scope of this guide.
Event format in this guide
This guide lists events by event code and severity, where the most severe form of an event is described first.
Events are listed in the following format. Events that do not apply to P2000 G3 MSA System products are
not listed.
Event code
Severity
Event description.
Recommended actions
Resources for diagnosing and resolving problems
For further information about diagnosing and resolving problems, see:
The troubleshooting chapter and the LED descriptions appendix in your product's user guide
The topic about verifying component failure in the component's replacement instructions document
These and other HP documents can be found
product or at http://www.hp.com/support/manuals.
http://www.hp.com/go/p2000
and software, see
For a summary of storage events and corresponding SMI-S indications, see
SMI-S clients
on page 45.
If the event indicates a problem, actions to take to resolve the problem.
or
http://www.hp.com/go/msa.
http://www.hp.com/support.
Software Support/Documentation CD
on the
For links to additional information about your product, see
For product support and to download drivers
HP P2000 G3 MSA System Event Descriptions Reference Guide
shipped with your
Events sent as indications to
3

Hide quick links:

Advertisement

loading

This manual is also suitable for:

P2000 g3