8
Warning
The indicated disk in the indicated vdisk failed and the vdisk changed to a critical or offline state. If a
spare is present the controller automatically uses the spare to reconstruct the vdisk. Subsequent events
indicate the changes which happen to the vdisk.
Recommended actions
See
Table 1
When the problem is resolved, event 9 is logged.
9
Info.
The indicated spare disk has been used in the indicated critical vdisk to bring it back to a fault-tolerant
state. Vdisk reconstruction starts automatically.
This event indicates that a problem reported by event 8 is resolved.
Recommended actions
No action required.
16
Info.
The indicated disk has been designated a global spare.
Recommended actions
No action required.
18
Warning
Vdisk reconstruction failed.
Recommended actions
Determine whether the reconstruction failed due to a disk problem and whether replacing that disk will
enable reconstruction to start and complete without further errors.
Info.
Vdisk reconstruction succeeded.
Recommended actions
No action required.
19
Info.
A rescan has completed.
Recommended actions
No action required.
20
Info.
Storage Controller firmware update has completed.
Recommended actions
No action required.
21
Warning
Vdisk verification failed during the verification process.
Recommended actions
See
Resources for diagnosing and resolving problems
Info.
Vdisk verification failed immediately, was aborted by a user, or succeeded.
Recommended actions
No action required.