8
Warning
The indicated disk in the indicated vdisk failed and the vdisk changed to a critical or offline state. If a
spare is present the controller automatically uses the spare to reconstruct the vdisk. Subsequent events
indicate the changes which happen to the vdisk.
Recommended actions
•
See
Table 1
When the problem is resolved, event 9 is logged.
9
Info.
The indicated spare disk has been used in the indicated critical vdisk to bring it back to a fault-tolerant
state. Vdisk reconstruction starts automatically.
This event indicates that a problem reported by event 8 is resolved.
Recommended actions
•
No action required.
16
Info.
The indicated disk has been designated a global spare.
Recommended actions
•
No action required.
18
Warning
Vdisk reconstruction failed.
Recommended actions
•
Determine whether the reconstruction failed due to a disk problem and whether replacing that disk will
enable reconstruction to start and complete without further errors.
Info.
Vdisk reconstruction succeeded.
Recommended actions
•
No action required.
19
Info.
A rescan has completed.
Recommended actions
•
No action required.
20
Info.
Storage Controller firmware update has completed.
Recommended actions
•
No action required.
21
Warning
Vdisk verification failed during the verification process.
Recommended actions
•
See
Resources for diagnosing and resolving problems
Info.
Vdisk verification failed immediately, was aborted by a user, or succeeded.
Recommended actions
•
No action required.
on page 42.
on page 3.
HP P2000 G3 MSA System Event Descriptions Reference Guide
5