Field Replaceable Units
FRU Removal and Replacement
1. Perform the procedures in the sections "Opening the System Unit Front Panel" and
"Opening the Left Side Panel of the System Unit." The front panel must be open to
remove the CD Drive from the system chassis. The left side panel needs to be opened so
you can get to the CD Drive's ATAPI connector and its power connector.
2. Remove the CD Drive rear disk cover by unscrewing the T-15 Torx screw as shown in
Figure 4-29. Note that the CD Drive's rear cover is located on the back of the removable
media chassis inside the system unit. Push the cover handle away from the back of the
removable media chassis approximately one inch. Next pull the cover handle toward
you. The ATAPI and power cables are now accessible to you. Disconnect these cables
from the CD Drive.
Figure 4-29. Removing the CD Drive's Rear Cover
3. Rotate the system unit around until you see the front of the unit as shown in Figure
4-30.
Figure 4-30. Front of the System Unit with the Front Panel Removed
4. Remove both CD Drive bracket screws (T-15 Torx screws) and pull the CD Drive out of
the chassis assembly as shown in Figure 4-31. Next remove the four CD Drive
122
Rear Cover
Audio
Cable
ATAPI Cable
Power Cable
LCD
Power Switch
Bracket Screw
Rear Cover
Handle
T-15
Torx/slotted
Screw
Bracket Screw
(hidden)
Chapter 4

Hide quick links:

Advertisement

Table of Contents
loading