Memory Failures - HP Visualize b1000 - Workstation Handbook

Unix workstations
Hide thumbs Also See for Visualize b1000 - Workstation:
Table of Contents

Advertisement

Table 3-2. Chassis Codes for B1000/C3000 Workstations
Ostat
Code
FRU
INI
CC4n
SYS BD
TST
D000
SYS BD
WRN
D004
SYS BD
INI
D005
SYS BD
INI
D006
SYS BD
WRN
D007
SYS BD
FLT
D01n
SYS/IO
WRN
D02n
SYS/IO

Memory Failures

The B1000/C3000 system requires Memory Page Deallocation to be implemented. This
feature allows the workstation to provide information to the operating system about
memory failures.
HP-UX 10.20 or later uses information to map out failing memory areas and continue
normal operation. You can use the command memrpt with the detail switch to obtain
information about the Memory Page Deallocation Table (PDT) as well as single-bit errors
logged by the system.
# /usr/sbin/sysdiag
DUI > logtool
LOGTOOL> memrpt detail
The PDT can also be checked using the pdt command in the Service menu of the Boot
Console Handler (refer to "Boot Console Menus" on page 159).
For allowable memory configurations see Chapter 2 of this manual.
Chapter 3
Message
CPU n mem rendez
micro controller
micro not resp
set dom1 fan spd
set dom2 fan spd
bad microctl cmd
fan n: failure!
fan n: too slow!
Enter
Enter
Enter
Description
Slave CPU n entering memory
rendezvous, waiting for the monarch CPU
to select a boot device.
Firmware is initializing communications
with the system controller.
Firmware detected a communications
error with the system controller.
Firmware is initializing communications
with the system controller.
Firmware is initializing communications
with the system controller.
Firmware detected a communications
error with the system controller.
Firmware detected system fan n stopped.
Firmware detected system fan n is
running too slowly.
Troubleshooting
Selftest Failures
83

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents