Field Replaceable Units
FRU Removal and Replacement
Figure 4-9. Disconnecting the Power Supply Cables
3. Remove the bail from the bail lock. See Figure 4-10.
4. Grasp the power supply by the handle and slide the spring hinge lever to the right and
rotate it downward to lock it in place. See Figure 4-10. This allows you pull outward on
the left side of the power supply while moving the power supply to the left as shown in
Figure 4-10. The power supply should be free from its left spring hinge and right hinge.
You can now remove the power supply from the system unit.
104
Power
Cable
Connectors
Control Cable
Connector
Chapter 4