Environmental Specifications
Environmental Specifications

Acoustics

Deskside: 4.7 bels typical @ 25˚ C
4.9 bels typical @ 30˚ C

Altitude

Operating:
0-10,000 ft. above sea level (0-3000m)
Non-operating (storage or shipping): 0-15,000 ft. above sea level (0-4500m)

DC Magnetic Field Interference

Operating: <1 Gauss at surface of product
Non-operating: <2 mGauss @ 7 feet

Electromagnetic Compatibility (EMC)

Emissions:
FCC Class B, CISPR B
Immunity:
EN61000-4-2: 1995 - 4KV contact discharge, 8KV air discharge (ESD)
EN61000-4-3: 1991 - 10V/m (radiated immunity)
EN61000-4-4: 1995 - 2kV signal lines, 4kV power lines (EFT)

Temperature

Operating:
5 to +40˚ C
Non-operating (shipping or storage): -40 to +70˚ C

Humidity (Non-condensing)

Operating:
15 to 80% RH
Non-operating: 0 to 90% RH (storage or shipping)

Leakage Current

Less than 3 milliamps

Shock

Operating: 20g at 3ms, 1/2 sine in normal axis with no hard errors
Non-operating (shipping): 80g at 3ms, 1/2 sine, normal axis