9. ERROR CODES
Error code
Loop length data, bobbin thread counter
data, production counter data or sewing
E-160
speed data is corrupted.
Lower shaft module was open
E-170
when sewing started.
Lower shaft module locking error
E-171
Upper thread breaks at the first
E-181
and second bar tacking.
182
Loop setting error
E-190
Communication error between
main circuit board and X-Y feed
E-1A0
circuit board.
Communication error between
main circuit board and panel
E-1A1
circuit board.
Motor does not operate, or problem
with synchronizer signal.
E-202
The pattern was found to be
outside the sewing area during a
E-203
scale check.
The pattern was found to be over
the maximum pitch during a scale
E-204
check.
Error detecting X or Y home
position for X-Y feed.
E-20A
Overheating of X-Y feed circuit
board
E-20D
Reading or writing error of
EEPROM on in X-Y feed circuit
E-20E
board
Problem
q Turn off power switch.
w Initialize the sewing data.
q Close the lower shaft.
w Press the RESET switch.
q Check the lock cylinder and sensor.
w Press the RESET switch.
Refer to pages 29.
q Remove the belt loop which was set incorrectly.
w Press the RESET switch.
e Press the LOOP switch and then set a new belt loop.
Press the RESET switch.
Press the RESET switch.
q Turn the machine pulley to check that it is not locked.
w Press the RESET switch.
Press the RESET switch and then reset the scale.
Press the RESET switch and then reset the scale.
Check the operation at the X or Y home position.
Turn off the power and check the operation of the
fan inside the box.
q Turn off power switch.
w Wait 10 seconds or more, and then turn the
72
Solution
power back on again.