PLC-HP7000L Expand Serial Command Functional Specifications
Acceptable
Response
%1
Unacceptable

9.10.40 CR_P-MANE Command

Command
"CR_P-MANE" [CR]
Details
Get setting status of Power management
Acceptable
Response
%1
Unacceptable

9.10.41 CR_P-MANETIME Command

Command
"CR_P-MAETIME" [CR]
Details
Get setting time for starting Power Management function
Acceptable
Response
%1
Unacceptable

9.10.42 CR_ON-STA Command

Command
"CR_ON-STA" [CR]
Details
Get Direct on setting status
Acceptable
Response
%1
Unacceptable

9.10.43 CR_POINTER Command

Command
"CR_POINTER" [CR]
Details
Get setting status of Pointer
Acceptable
Response
%1
Unacceptable

9.10.44 CR_PTIMEMODE Command

Command
"CR_PTIMEMODE" [CR]
Details
Get setting status of count up/down mode in P-timer
Response
Acceptable
"000_%1" [CR]
"IR" -------- IR
"RF" ------- RF (cannot be returned as this model supports only
IR remote control)
"Error Code" [CR]
"000_%1" [CR]
"OFF" ------------------------ Power Management is disabled
"READY1" -------------------- Power Management is set to
Ready1
"READY2" -------------------- Power Management is set to
Ready2
"SHUTDOWN" ------------ Power Management is set to Shut
Down mode
"Error Code" [CR]
"000_%1" [CR]
"001 – 030" ----------------------- 1 to 30 minutes
"Error Code" [CR]
"000_%1" [CR]
"ON" -------------------------- Direct on is active
"OFF" ------------------------ Direct on is inactive
"Error Code" [CR]
"000_%a" [CR]
"ARROW" ---------------------Arrow Pointer mode
"FINGER" ---------------------Finger Pointer mode
"LASER" ---------------------- Dot Pointer mode
"Error Code" [CR]
"000_%a" [CR]