PLC-HP7000L Expand Serial Command Functional Specifications Overview ・ This Functional Specification defines communication with PJ-Net organizer for PLC-HP7000L. ・ Supporting Firmware Ver. 1.x of the projector. ・ Commands in this document are to communicate with PJ-Net organizer, but most commands are used to control a projector remotely from a computer with RS-232C.
PLC-HP7000L Expand Serial Command Functional Specifications Notes for communication Expand Serial Command is defined as a single command per line that starts with “C” and ends with carriage return (0x0D). There are two types of commands; Functional Execution Commands and Status Read Command.
PLC-HP7000L Expand Serial Command Functional Specifications Functional Execution Command Table 5.1 Image Command Table Item Execute command CF_BRIGHT_%1 [CR] Set value of Brightness CF_CONT_%1 [CR] Set value of Contrast CF_COLOR_%1 [CR] Set value of Color CF_TINT_%1 [CR] Set value of Tint...
PLC-HP7000L Expand Serial Command Functional Specifications Screen Control Command Table Execute command Item CF_SCREEN_%1 [CR] Select Screen size CF_DZCENT _%1 [CR] Cancel Digital Zoom mode CF_VSCALE_%1[CR] Set V Scale CF_VPOS_%1[CR] Set V Position CF_HSCALE_%1[CR] Set H Scale CF_HPOS_%1[CR] Set H Position...
PLC-HP7000L Expand Serial Command Functional Specifications CF_BLENDMENUOFF_%1[CR Set Menu off function in Edge blending ] CF_BLENDMENU_%1[CR] Select display or erase Edge blending menu. CF_COLORMATCHING_%1[C Set Color matching CF_CMMSXY_%1_%2_%3[CR] Set “x,y” value of Measured for Color matching CF_CMMSL_%1_%2[CR] Set “L” value of Measured for Color matching CF_CMTGXY_%1_%2_%3[CR] Set “x,y”...
PLC-HP7000L Expand Serial Command Functional Specifications Status Read Command Table Image Status Read Command Table Status Read command Item CR_BRIGHT [CR] Get value of Brightness CR_CONT [CR] Get value of Contrast CR_COLOR [CR] Get value of Color CR_TINT [CR] Get value of Tint...
PLC-HP7000L Expand Serial Command Functional Specifications CR_NMSLOT2[CR] Get terminal information of Input2. CR_NMSLOT3[CR] Get terminal information of Input3 CR_NMSLOT4[CR] Get terminal information of Input4. CR_IDSLOT1[CR] Get ID information of Input1 CR_IDSLOT2[CR] Get ID information of Input2 CR_IDSLOT3[CR] Get ID information of Input3...
PLC-HP7000L Expand Serial Command Functional Specifications CR_COLORMATCHING Get setting status of Color matching [CR] CR_CMMSXY_%1[CR] Get “x”,”y” value of Measured of Color matching CR_CMMSL_%1[CR] Get “L” value of Measured of Color matching CR_CMTGXY_%1[CR] Get “x”,”y” value of Target of Color matching CR_CMTGG_%1[CR] Get “g”...
PLC-HP7000L Expand Serial Command Functional Specifications Error Code Table Error Code Contents -When the received data cannot be decoded -Parameter designation error (wrong digit number, including invalid value, etc.) Normal reception (This is “Not” error) The function is not available in the selected Mode...
PLC-HP7000L Expand Serial Command Functional Specifications Functional Execution Command 8.1 Format 1) PC issues commands in format as below: Pattern1: “CF_ COMMAND” [CR] Pattern2: “CF_ COMMAND _” %1 [CR] CF_: Header COMMAND: String %1: Parameter (String) _: Space (To separate COMMAND and Parameter) 2) The projector decodes the received command and when it is ready to receive the next command, it returns the response.
PLC-HP7000L Expand Serial Command Functional Specifications Image Command 8.4.1 CF_ BRIGHT Command Command “CF_BRIGHT_%1” [CR] “000-063”--------------- Directly specify setting value of Brightness “UP”--------------------- Increment setting value of Brightness by 1 “DN”--------------------- Decrement setting value of Brightness by 1 Set user controlled value of Brightness (Available only in the normal Power ON...
PLC-HP7000L Expand Serial Command Functional Specifications 8.4.5 CF_COLMNSAV Command Command “CF_COLMNSAV_%1” [CR] “000 – 009” ---------------- Specify the area to store Store current setting status of Color Management to the area specified in %1. Details (Available only in the normal Power ON status) Acceptable “000”...
PLC-HP7000L Expand Serial Command Functional Specifications 8.4.9 CF_WBAL- Command Command “CF_WBAL-%1_%2” [CR] “R” --------- RED “G” --------- GREEN “B” --------- BLUE “000-063”------ Directly specify value of Color selected in %1 of White Balance. “UP”-------- Increment setting value of Color specified in %1 of White Balance by 1 “DN”------- Decrement setting value of Color specified in %1 of White Balance by 1...
PLC-HP7000L Expand Serial Command Functional Specifications *”UP” and “DN” are exactly same operation. Set Noise Reduction level (Available only in the normal Power ON status) The value set by this command will not be stored in the projector’s memory Details Therefore, when the power is turned to ALL OFF status, the value returns to the original setting.
PLC-HP7000L Expand Serial Command Functional Specifications 8.4.15 CF_IMAGEADJ Command Command “CF_IMAGEADJ_%1”[CR] “RST”------ Reset adjusted value for the Image “STR1”---- Store current adjusted value to Image 1 “STR2”---- Store current adjusted value to Image 2 “STR3”---- Store current adjusted value to Image 3 “STR4”---- Store current adjusted value to Image 4...
PLC-HP7000L Expand Serial Command Functional Specifications PC Adjust Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1” [CR] “0000-0031” ----------------- Directly specify setting value of Fine Sync “UP” --------------------------- Increment setting value of Fine Sync by 1 “DN” --------------------------- Decrement setting value of Fine Sync by 1...
PLC-HP7000L Expand Serial Command Functional Specifications 8.5.4 CF_H-POS Command Command “CF_H-POS_%1” [CR] “0000-nnnn” -------- Directly specify setting value of Horizontal Position “nnnn” indicates maximum value, which is current value of (Total dots - Display area H) “UP” ------------------- Increment setting value of Horizontal Position by 1 “DN”...
PLC-HP7000L Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command “CF_DLINE_%1” [CR] “0100-nnnn” ----------- Directly specify setting value of Display Line “nnnn” indicates maximum value, which is current value of (Total Line - Position V). “UP” ------------------- Increment setting value of Display Line by 1 “DN”...
PLC-HP7000L Expand Serial Command Functional Specifications 8.5.11 CF_PCMODEFREE Command Command “CF_PCMODEFREE_%1” [CR] “1” --------------------------- Set Mode1 to Free status “2” --------------------------- Set Mode2 to Free status “3” --------------------------- Set Mode3 to Free status “4” --------------------------- Set Mode4 to Free status “5”...
PLC-HP7000L Expand Serial Command Functional Specifications 8.7.7 CF_KEYSTONE Command Command “CF_KEYSTONE _%1” [CR] “UP” ------------- Correct Keystone distortion to reduce upper part of image “FUP” ----------- Correct Keystone distortion to reduce upper part by 2 steps “DN” ------------- Correct Keystone distortion to reduce lower part of image “FDN”...
PLC-HP7000L Expand Serial Command Functional Specifications 8.7.10 CF_CORNER-UR Command Command “CF_CORNER-UR_%1”[CR] “UP” ------------ Correct the horizontal line of image upwards “DN” ------------ Correct the horizontal line of image downwards “LEFT” --------- Correct the vertical line of image to the left “RIGHT”...
PLC-HP7000L Expand Serial Command Functional Specifications 8.7.13 CF_CORNERTESTPAT Command Command “CF_CORNERTESTPAT_%1”[CR] “RED” ------------Select Red “WHITE” -------- Select White “BLUE” ---------- Select Blue “OFF” ------------ Select Off Display test patterns for Corner correction. (Available in normal Power ON status only) Details The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF.
PLC-HP7000L Expand Serial Command Functional Specifications 8.9.4 CF_INPUTBUTTON Command Command “CF_INPUTBUTTON_%1” [CR] “MODE1” ------------------------- Set Input button operation to MODE1 “MODE2” ------------------------- Set Input button operation to MODE2 “MODE3” ------------------------- Set Input button operation to MODE3 Set Input button operation mode. (Available in normal Power ON status only).
PLC-HP7000L Expand Serial Command Functional Specifications 8.9.7 CF_LOGO Command Command “CF_LOGO_%1_%2” [CR] “0000 – 9999” ------------- Directly set Logo PIN code “OFF” ---------------------------Cancel Logo display “DFLT” ------------------------- Select Logo of Factory Default “USER” ------------------------ Select User “UP” ---------- The same operation as pressing Up key or Left key “DN”...
PLC-HP7000L Expand Serial Command Functional Specifications (Valid only when in the normal Power ON status.) *When “Picture in Picture” is set to Off, return “101” [CR] Acceptable “000” [CR] Response Unacceptable “Error Code” [CR] 8.9.13 CF_PIPPOSITION Command Command “CF_PIPPOSITION_%1” [CR] “POS1”...
PLC-HP7000L Expand Serial Command Functional Specifications 8.9.16 CF_PIPMODEFREE Command Command “CF_PIPMODEFREE_%1” [CR] “USER1” --------------------------- Set User1 to Free status “USER 2” -------------------------- Set User2 to Free status “USER 3” -------------------------- Set User3 to Free status “USER 4” -------------------------- Set User4 to Free status “USER 5”...
PLC-HP7000L Expand Serial Command Functional Specifications 8.9.20 CF_BLENDSTART Command Command “CF_BLENDSTART_%1_%2” [CR] “LEFT” ---------------------- Left side “RIGHT” -------------------- Right side “TOP” ----------------------- Upper side “BOTTOM” ---------------- Lower side “000”-“1024”-------------------- Directly specify value of direction of %1 *Value of upper limit changes by choice of %1...
PLC-HP7000L Expand Serial Command Functional Specifications Acceptable “000” [CR] Response Unacceptable “Error Code” [CR] 8.9.24 CF_BLENDRST Command Command “CF_BLENDRST_%1” [CR] “RST” ---------------------- Reset current setting status Reset current setting status of Edge blending. Details (Available only in the normal Power ON status) Acceptable “000”...
PLC-HP7000L Expand Serial Command Functional Specifications Set “x”,”y” value of Measured of Color matching. Details (Available only in the normal Power ON status) Acceptable “000” [CR] Response Unacceptable “Error Code” [CR] 8.9.29 CF_CMMSL Command Command “CF_CMMSL_%1_%2” [CR] “RED” ---------------------- Set value of Red “GREEN”...
PLC-HP7000L Expand Serial Command Functional Specifications “ON” ---------------------- Set to On “OFF” -------------------- Set to Off Set Auto test pattern of Color matching. Details (Available only in the normal Power ON status) Acceptable “000” [CR] Response Unacceptable “Error Code” [CR] 8.9.33...
PLC-HP7000L Expand Serial Command Functional Specifications 8.9.37 CF_CMFDEFAULT Command Command “CF_CMFDEFAULT_%1” [CR] “RST” ---------------------- Reset the value of Target Return the value of Advanced color matching to Factory Default status Details (Available only in the normal Power ON status) Acceptable “000”...
PLC-HP7000L Expand Serial Command Functional Specifications “0400” ---------------------- Set 400 hours “0700” ---------------------- Set 700 hours “1000” ---------------------- Set 1000 hours “OFF” ---------------------- Set Off(Do not warning display) Details Set time to display Filter cleaning / replacement warning on screen Acceptable “000”...
PLC-HP7000L Expand Serial Command Functional Specifications 8.9.51 CF_ON-STA Command Command “CF_ON-STA_%1” [CR] “ON” --------------------------- Set Direct on active. “OFF” ------------------------- Set Direct on inactive. “UP” ---------- The same operation as pressing Up key or Left key “DN” ----------The same operation as pressing Down key or Right key *”UP”...
PLC-HP7000L Expand Serial Command Functional Specifications “001” – “180” -------------------------- Directly specify setting time Set the time for Count down mode of P-timer. (Available only in the normal Power ON status) Details The status set by this command is stored in EEPROM and setting value remains effective even after the power is turned to ALL OFF status.
PLC-HP7000L Expand Serial Command Functional Specifications 8.9.59 CF_SHUTRELEASE Command Command “CF_SHUTRELEASE_%1” [CR] “ANY”--------------------Enable to release Shutter with any key “SHUTTER” ---------- Enable to release Shutter with only “SHUTTER” key Set Release key of Shutter. (Valid only when in the normal Power ON status)
PLC-HP7000L Expand Serial Command Functional Specifications 8.9.63 CF_DELAYCTRL Command Command “CF_DELAYCTRL_%1” [CR] “OFF”---------- Set Video delay control to OFF “LOW”---------- Set Video delay control to LOW “MID”---------- Set Video delay control to MID “HIGH”---------- Set Video delay control to HIGH...
PLC-HP7000L Expand Serial Command Functional Specifications 8.10.3 CF_POWER Command Command “CF_POWER_%1” [CR] “ON” ----------------------------- Power ON “OFF” --------------------------- Power OFF * Issuing another command during countdown process forced countdown operation to be terminated. * Error Code is returned in some projector statuses, which indicates the command is impossible to be executed.
PLC-HP7000L Expand Serial Command Functional Specifications Status Read Command 9.1 Format PC issues commands in format as below: “CR_ COMMAND” [CR] Command: String When projector receives the appropriate command, it returns the required data as a string. “000_” %1 [CR] %1: Required Data (String) When the received data cannot be decoded, the projector returns “?”...
PLC-HP7000L Expand Serial Command Functional Specifications 9.4.6 CR_SHARP Command Command “CR_SHARP” [CR] Details Get user controlled value of Sharpness Acceptable “000_%1” [CR] Response “000 – 031” Unacceptable “Error Code” [CR] 9.4.7 CR_GAMMA Command Command “CR_GAMMA” [CR] Details Get user controlled value of Gamma Acceptable “000_%1”...
PLC-HP7000L Expand Serial Command Functional Specifications 9.4.11 CR_COLTEMP Command Command “CR_COLTEMP” [CR] Details Get Color Temperature setting status Acceptable “000_%1” [CR] “000” --------------------------------- Xlow “001” --------------------------------- Low “002” --------------------------------- Mid Response “003” --------------------------------- High “BLANK” ---- OSD Menu is blank...
PLC-HP7000L Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command “CR_FSYNC” [CR] Details Get value of Fine Sync Acceptable “000_%1” [CR] “0000 – 0031” Response “Error Code” [CR] --- When command is not available in the given...
PLC-HP7000L Expand Serial Command Functional Specifications 9.5.6 CR_DDOTS Command Command “CR_DDOTS” [CR] Details Get value of Display Dots Acceptable “000_%1” [CR] “0100 – nnnn” (nnnn = Total Dots – Position H) Response “Error Code” [CR] ---- When command is not available in the...
PLC-HP7000L Expand Serial Command Functional Specifications 9.5.8 CR_ORGMODE Command Command “CR_ORGMODE” [CR] Get the original signal of current selected Mode that is set in PC Adj. Details When MODE1- 10 or EXT11-50 is not selected, get the current signal. Acceptable “000_%1”...
PLC-HP7000L Expand Serial Command Functional Specifications 9.5.10 CR_SETPCADJ Command Command “CR_SETPCADJ” [CR] Details Get PC signal for current system Acceptable “000_%1” [CR] When input signal is PC Analog; “VGA1” ------------------------ Indicates VGA1 is selected “VGA2” ------------------------ Indicates VGA2 is selected “XGA1”...
PLC-HP7000L Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command “CR_SERSYS” [CR] Get selected current signal. Auto detected signal is returned in Auto mode Details Only available when Input is Y,Pb/Cb,Pr/Cr, S-Video or Video. (This is not the case...
PLC-HP7000L Expand Serial Command Functional Specifications 9.7.8 CR_SYSLIST Command Command “CR_SYSLIST” [CR] Details Get possible systems for System list Acceptable “000_%1_%2_---_%x” [CR] Error Code “101” is returned for no signal. Otherwise following values are returned according to Source. When input is PC-Analog;...
PLC-HP7000L Expand Serial Command Functional Specifications 9.7.10 CR_HMSLOT Command Command “CR_HMSLOT” [CR] Details Get the total number of Input. Acceptable “000_%1” [CR] “004” ------------ When PJ-Net is attached. Response “003” ------------ When PJ-Net is not attached. Unacceptable “Error Code” [CR] 9.7.11 CR_NMSLOT1 Command...
PLC-HP7000L Expand Serial Command Functional Specifications 9.7.15 CR_IDSLOT1 Command Command “CR_IDSLOT1” [CR] Get ID information of Input1. This command is to determine sources possible to Details input. Acceptable “000_%1” [CR] “32” --------------- On-board (HDMI and D-Sub) Response Available source: DIGITAL, ANALOG, SCART, HDCP, HDMI Unacceptable “Error Code”...
PLC-HP7000L Expand Serial Command Functional Specifications 9.8.6 CR_ KYSTNMODE Command Command “CR_KYSTNMODE” [CR] Details Get setting status of Keystone Store Mode Acceptable “000_%1” [CR] “STR” ---------------------- Store mode is “Store” Response “RST” ---------------------- Store mode is “Reset” Unacceptable “?” [CR] -------------------- When unknown command is received 9.8.7...
PLC-HP7000L Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL” [CR] Details Get information of Lamp Replacement time Acceptable “000_%1” [CR] “1Y” ----------------- indicates over lamp replacement time Response “1N” ----------------- indicates under lamp replacement time Unacceptable “?”...
PLC-HP7000L Expand Serial Command Functional Specifications 9.9.6 CR_PROJH Command Command “CR_PROJH” [CR] Details Get total running time of Projector (in hours) Acceptable “000_%1” [CR] Response “0000000 – 0099999” Unacceptable “Error Code” [CR] 9.9.7 CR_HMLAMP Command Command “CR_HMLAMP” [CR] Details Get total lamp number Acceptable “000_%1”...
PLC-HP7000L Expand Serial Command Functional Specifications 9.10 Setting Status Read Command 9.10.1 CR_LANG Command Command “CR_LANG” [CR] Details Get selected language Acceptable “000_%1” [CR] “ENG” -------------------------- English is selected “DEU” -------------------------- German is selected “FRA” -------------------------- French is selected “ITA” --------------------------- Italian is selected “ESP”...
PLC-HP7000L Expand Serial Command Functional Specifications 9.10.5 CR_BACKGND Command Command “CR_BACKGND” [CR] Details Get setting status of Screen for no signal Acceptable “000_%1” [CR] “BLUE” -------------------------------- Blue Back is selected Response “USER” ------------------------------- User is selected “BLACK” ------------------------------ Black Back is selected Unacceptable “Error Code”...
PLC-HP7000L Expand Serial Command Functional Specifications 9.10.10 CR_PIPMODE Command Command “CR_PIP” [CR] Details Get Mode in “Picture in Picture” Acceptable “000_%1” [CR] “PINP” ----------------- P in P is selected Response “PBYP” ---------------- P by P is selected Unacceptable “Error Code” [CR] 9.10.11 CR_PIPMAININP Command...
PLC-HP7000L Expand Serial Command Functional Specifications Left width data comes first, and then one space, after that right width data is followed. %1 = Left width %2 = Right width %3 = Top width %4 = Bottom width %1, %2, %3, %4 e.g.
PLC-HP7000L Expand Serial Command Functional Specifications Acceptable “000_%1” [CR] “ON” ---------------------- On is selected Response “OFF” --------------------- Off is selected Unacceptable “Error Code” [CR] 9.10.21 CR_COLORMATCHING Command Command “CR_COLORMATCHING” [CR] Details Get setting status of Color matching Acceptable “000_%1” [CR] “ON”...
PLC-HP7000L Expand Serial Command Functional Specifications Unacceptable “Error Code” [CR] 9.10.25 CR_ CMTGG_%1 Command Command “CR_CMMTGG_%1” [CR] Details Get “g” value of Target of Color matching Acceptable “000_%2” [CR] “RED” ---------------------- value of Red is selected “GREEN” ----------------- value of Green is selected “BLUE”...
PLC-HP7000L Expand Serial Command Functional Specifications Acceptable “000_%1” [CR] “1Y”-------Filter Exchange time is over value of Filter Message. Response “1N”--Filter Exchange time is not over value of Filter Message. Unacceptable “Error Code” [CR] 9.10.35 CR_FANSPEED Command Command “CR_FANSPEED” [CR] Details Get selected Fan Control Speed mode.
PLC-HP7000L Expand Serial Command Functional Specifications Acceptable “000_%1” [CR] “IR” -------- IR Response “RF” ------- RF (cannot be returned as this model supports only IR remote control) Unacceptable “Error Code” [CR] 9.10.40 CR_P-MANE Command Command “CR_P-MANE” [CR] Details Get setting status of Power management Acceptable “000_%1”...
PLC-HP7000L Expand Serial Command Functional Specifications “COUNTUP” -------------------- Set P-timer to Count up mode “COUNTDN” -------------------- Set P-timer to Count down mode Unacceptable “Error Code” [CR] 9.10.45 CR_PTIMER Command Command “CR_PTIMER” [CR] Details Get setting status of P-timer Acceptable “000_%a” [CR] “ON”...
PLC-HP7000L Expand Serial Command Functional Specifications “LOCK” ------ PJ is locked PIN code lock is set to ON1/ON2 on the menu and PJ PIN code is not entered, therefore PJ is actually locked. “FREE” ------- PJ is unlocked (either A or B)
PLC-HP7000L Expand Serial Command Functional Specifications 9.11 Other Status Read Commands 9.11.1 CR_STATUS Command COMMAND “CR_STATUS” [CR] Get operating status of Projector Detail Same as “CR0” in basic command except error code follows it. Acceptable “000_%1” [CR] “00” = Power ON “80”...
PLC-HP7000L Expand Serial Command Functional Specifications 9.11.5 CR_TEMPFAIL Command Command “CR_TEMPFAIL” [CR] Get the temperature inside a projector when abnormal temperature status Details occurs. It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp.
PLC-HP7000L Expand Serial Command Functional Specifications 9.11.6 CR_TEMP Command Command “CR_TEMP” [CR] Get the current temperature information inside a projector. Details It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp. (External temp.) %2 ------------------ Sensor 2 temp.