Functional Execution Command; Format; Transfer Example; Operation Requirements - Sanyo PLC-HP7000L Technical Specifications

Expand serial command functional specifications
Hide thumbs Also See for PLC-HP7000L:
Table of Contents

Advertisement

PLC-HP7000L Expand Serial Command Functional Specifications
8

Functional Execution Command

8.1 Format

1) PC issues commands in format as below:
Pattern1: "CF_ COMMAND" [CR]
Pattern2: "CF_ COMMAND _" %1 [CR]
2) The projector decodes the received command and when it is ready to receive the next
command, it returns the response.
"000" [CR]:(0x06,0x0D)When receiving Functional Execution Command
"nnn" [CR]: Except "000", when it is unable to execute command for any specific reason.
3) When the received data cannot be decoded, the projector returns "?" [CR]

8.2 Transfer Example

When setting projector's total dots to 1344 by Expand Serial command
PC → PJ: "CF_TDOTS_1344" [CR]
PC → PJ: "000" [CR] - - - - - - - - - - Acceptable

8.3 Operation Requirements

1. Functional Execution Command is limited when the projector status is as below.

However, Status Read Command is still effective under following conditions.
Projector Status
Standby Mode
Countdown in process
Cooling Down in process
Cooling Down due to
Abnormal Temperature
Abnormal Temperature
Power Failure
(60 seconds after Power failure occurred)
Abnormal Filter
Power-Save Cooling Down in process
Cooling Down in process due to
Shutter management
Power Save in process
Note) When projector receives another command in the above status, it returns error code which
shows the status.
CF_: Header
COMMAND: String
%1: Parameter (String)
_: Space (To separate COMMAND and Parameter)
See Error Code Table for details
Available Functional Execution Command
C00: Power ON
CF POWER ON
C00: Power ON
CF POWER ON (Terminates Count Down)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
C00: Power ON
C01: Power OFF
CF POWER ON
CF POWER OFF
19/94

Advertisement

Table of Contents
loading

Table of Contents