PLC-HP7000L Expand Serial Command Functional Specifications
8.8
Lamp Command
8.8.1
CF_LAMPH Command
Command
"CF_LAMPH_%1" [CR]
%1
"RST"
Details
Reset lamp running time (Available only in the normal Power ON status)
Acceptable
Response
Unacceptable
8.8.2
CF_LAMPMODE Command
Command
"CF_LAMPMODE_%1" [CR]
"NORMAL" ------------------------ Set Lamp status to Normal mode
"ECO1" ------------------------------- Set Lamp status to Eco1 mode
%1
"ECO2" ------------------------------- Set Lamp status to Eco2 mode
"AUTO" ----------------------------- Set Lamp status to Auto mode
Select Lamp mode (Available only in the normal Power ON status)
Details
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
39/94