Cf_On-Sta Command; Cf_Pointer Command; Cf_Ptimemode Command; Cf_Ptimer Command - Sanyo PLC-HP7000L Technical Specifications

Expand serial command functional specifications
Hide thumbs Also See for PLC-HP7000L:
Table of Contents

Advertisement

PLC-HP7000L Expand Serial Command Functional Specifications

8.9.51 CF_ON-STA Command

Command
"CF_ON-STA_%1" [CR]
"ON" --------------------------- Set Direct on active.
"OFF" ------------------------- Set Direct on inactive.
%1
"UP" ---------- The same operation as pressing Up key or Left key
"DN" ----------The same operation as pressing Down key or Right key
*"UP" and "DN" are exactly same operation.
Set/Cancel Direct Power On (Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.9.52 CF_POINTER Command

Command
"CF_POINTER_%1" [CR]
"ARROW" ---------------------- Select Arrow Pointer
%1
"FINGER" ---------------------- Select Finger Pointer
"LASER" ---------------------- Select Dot Pointer
Select indication of Pointer. (Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.9.53 CF_PTIMEMODE Command

Command
"CF_PTIMEMODE_%1" [CR]
"COUNTUP" ---------------------- Set P-timer to Count up mode
%1
"COUNTDN" ---------------------- Set P-timer to Count down mode
Select count up/down mode of P-timer.
(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.9.54 CF_PTIMER Command

Command
"CF_PTIMER_%1" [CR]
"START" -------------------------- Start P-timer
"STOP" ---------------------------- Stop P-timer
%1
"RESTART" ---------------------- Resume P-timer
"RST" ------------------------------ Reset P-timer
"EXIT" ----------------------------- Exit P-timer function
Select the status of P-timer.
Details
(Available only in the normal Power ON status)
Acceptable
Response
Unacceptable

8.9.55 CF_PTIME Command

Command
"CF_PTIME_%1" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
53/94