HP Visualize c100 Service Handbook page 98

C class
Hide thumbs Also See for Visualize c100:
Table of Contents

Advertisement

Field Replaceable Units
This chapter lists the C100/110 Field Replaceable
Units (FRUs) and provides procedures and illustra-
tions showing their removal and replacement.
Use the following tools to remove or replace FRUs:
WARNING
To avoid electrical shock, you must power off
the system and unplug the power cord from the
wall outlet, before performing each of the
procedures in this chapter.
NOTICES:
There is no need to manually shutdown the HP-UX
operating system on the workstation before
switching it off. When the power switch is turned
off, the workstation automatically shuts down the
operating system before terminating the power.
To maintain FCC/EMI compliance, verify that all
covers, bezels, and modules are replaced and that
all screws are properly seated.
Failing to push the main tray all the way in and
tighten the four screws on the back may prevent
the system from powering up.
84
Light-duty flat blade screwdriver with 150-mm (6-in.)
blade
ESD equipment (see the "ESD Precautions" section in
the Preface for detailed information)