Is the drive enclosure Fault/Service Required LED
amber?
Answer
No
Yes
(blinking)
Yes
62
HP StorageWorks 2012sa Modular Smart Array user guide • May 2008
Possible Reasons
System functioning properly.
One of the following errors
occurred:
• Hardware-controlled power-
up error
• Cache flush error
• Cache self-refresh error
A fault occurred.
If installing an I/O module
FRU, the module has not gone
online and likely failed its self-
test.
Actions
No action required.
• Check the event log for specific
information regarding the fault.
• Isolate the fault.
• Contact an authorized service
provider for assistance.
• Replace if necessary.
• Check the event log for specific
information regarding the fault.
• Isolate the fault.
• Contact an authorized service
provider for assistance.
• Replace if necessary.
• If installing an I/O module FRU,
try removing and reinstalling the
new I/O module, and check the
event log for errors.
Need help?
Do you have a question about the AA988A - Modular Smart Array Storage Controller SCSI and is the answer not in the manual?
Questions and answers