4. Move the expansion cable to a port on the RAID enclosure with a known good link
status.
This step isolates the problem to the expansion cable or to the controller module's
expansion port.
Is the expansion port status LED on?
Yes – You now know that the expansion cable is good. Return cable to the
■
original port. If the expansion port status LED remains off, you have isolated
the fault to the controller module's expansion port. Replace the controller
module.
No – Proceed to the next step.
■
5. Move the expansion cable back to the original port on the controller enclosure.
6. Move the expansion cable on the drive enclosure to a known good expansion port
on the drive
enclosure.
Is the expansion port status LED on?
Yes – You have isolated the problem to the drive enclosure's port. Replace the
■
expansion module.
No – Proceed to Step 7.
■
7. Replace the cable with a known good cable, ensuring the cable is attached to the
original ports used by the previous cable.
Is the host link status LED on?
Yes – Replace the original cable. The fault has been isolated.
■
No – It is likely that the controller module needs to be replaced
■
Chapter 5 Troubleshooting