4. In the terminal emulator, connect to controller A.
5. Press Enter to display the CLI prompt (#).
6. At the prompt, type the following command to set the values you obtained in Step 1
for each Ethernet management port, first for controller A and then for controller B:
set network-parameters ip address netmask netmask gateway gateway
controller a|b
where:
address is the IP address of the controller
netmask is the subnet mask
gateway is the IP address of the subnet router
a|b
For example:
# set network-parameters ip 192.168.0.10 netmask 255.255.255.0
gateway 192.168.0.1 controller a
# set network-parameters ip 192.168.0.11 netmask 255.255.255.0
gateway 192.168.0.1 controller b
7. Type the following command to verify the new IP addresses:
show network-parameters
44
HP StorageWorks 2012sa Modular Smart Array user guide • May 2008
specifies the controller whose network parameters you are setting