Is The Power-And-Cooling Module Dc Voltage/Fan Fault/Service Required Led Amber; Is The Drive Enclosure Back Panel Ok Led Off - HP AA988A - Modular Smart Array Storage Controller SCSI User Manual

Hp storageworks 2012sa modular smart array user guide (488320-002, july 2008)
Hide thumbs Also See for AA988A - Modular Smart Array Storage Controller SCSI:
Table of Contents

Advertisement

Is the power-and-cooling module DC Voltage/Fan
Fault/Service Required LED amber?
Answer
Possible Reasons
No
System functioning properly.
Yes
The power supply unit or a fan
is operating at an unacceptable
voltage/RPM level, or has
failed.

Is the drive enclosure back panel OK LED off?

Answer
Possible Reasons
No
System functioning properly
Yes
• The expansion module is not
powered on.
• The controller module has
failed.
Actions
No action required.
When isolating faults in the power-
and-cooling module, remember that
the fans in both modules receive
power through a common bus on the
midplane, so if a power supply unit
fails, the fans continue to operate
normally.
• Check that the power-and-cooling
supply FRU is firmly locked into
position.
• Check that the AC cord is
connected to a power source.
• Check that the AC cord is
connected to the power-and-
cooling module.
Actions
No action required
• Check that the drive is fully
inserted and latched in place,
• Check that the enclosure is
powered on.
• Check that the AC cord is
connected to a power source.
• Check the event log for specific
information regarding the failure.
Chapter 5 Troubleshooting
61

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AA988A - Modular Smart Array Storage Controller SCSI and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Storageworks 2012sa

Table of Contents