McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Manual page 92

Fw 08.01.00 mcdata e/os snmp support manual (620-000131-630, november 2005)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

McDATA SNMP Support
2
FcFxPortRatov
FcFxPortEdtov
FcFxPortCosSupported
fcFxPortIntermixSupported
E/OS SNMP Support Manual
2-70
This is fixed at 2112.
MilliSeconds
Type
PCP
Provided By
R
Access
The Resource_Allocation_Timeout Value configured for the Fx_Port.
Description
This is used as the timeout value for determining when to reuse an
NxPort resource such as a Recovery_Qualifier. It represents
E_D_TOV (see next object) plus twice the maximum time that a frame
may be delayed within the Fabric and still be delivered.
MilliSeconds
Type
PCP
Provided By
R
Access
The E_D_TOV value configured for the Fx_Port. The
Description
Error_Detect_Timeout Value is used as the timeout value for
detecting an error condition.
FcCosCap
Type
SNMP
Provided By
R
Access
A value indicating the set of Classes of Service supported by the
Description
Fx_Port.
This is fixed at CLASS_2 | CLASS_3 (0x0C).
INTEGER
Type
SNMP
Provided By
R
Access

Advertisement

Table of Contents
loading

Table of Contents