FC Management MIB
B
connUnitPortStatCountRxMulticastObjects
connUnitPortStatCountTxMulticastObjects
connUnitPortStatCountRxBroadcastObjects
connUnitPortStatCountTxBroadcastObjects
E/OS SNMP Support Manual
B-58
Count of Class 3 Frames that were discarded upon reception at this
Description
port. There is no FBSY or FRJT generated for Class 3 Frames. They
are simply discarded if they cannot be delivered. Note, this is a Fibre
Channel only stat.
Sequence
::= { connUnitPortStatEntry 28 }
OCTET STRING (SIZE (8))
Syntax
read-only
Access
mandatory
Status
Count of Multicast Frames or Packets received at this port.
Description
Sequence
::= { connUnitPortStatEntry 29 }
OCTET STRING (SIZE (8))
Syntax
read-only
Access
mandatory
Status
Count of Multicast Frames or Packets transmitted out this port.
Description
Sequence
::= { connUnitPortStatEntry 30 }
OCTET STRING (SIZE (8))
Syntax
read-only
Access
mandatory
Status
Count of Broadcast Frames or Packets received at this port.
Description
Sequence
::= { connUnitPortStatEntry 31 }
OCTET STRING (SIZE (8))
Syntax
read-only
Access
mandatory
Status