trapRegPort
Syntax
Access
Status
Description
Sequence
trapRegFilter
Syntax
Access
Status
Description
Sequence
trapRegRowState
Syntax
Access
Status
Description
INTEGER (1..2147483647)
read-only
mandatory
The UDP port to send traps to for this host. Normally this would be
the standard trap port (162). This object is an index and must be
specified to create a row in this table.
::= { trapRegEntry 2 }
FcEventSeverity
read-write
mandatory
This value defines the trap severity filter for this trap host. The
connUnit will send traps to this host that have a severity level less
than or equal to this value. The default value of this object is
'warning'.
::= { trapRegEntry 3}
INTEGER {
rowDestroy(1),
Remove row from table.
rowInactive(2),
Row exists, but TRAPs disabled
rowActive(3)
Row exists and is enabled for sending traps }
read-write
mandatory
Specifies the state of the row.
rowDestroy
READ: Can never happen.
WRITE: Remove this row from the table.
FC Management MIB