IBM 8863 - eServer xSeries 366 Service Manual page 83

Problem determination and service guide
Hide thumbs Also See for 8863 - eServer xSeries 366:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8863," on page 93 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)", that step must be performed only by a
trained service technician.
Error code
Description
089-xxx-0nn
Failed microprocessor test, where
nn=APIC ID.
APIC ID (physical mode)
00, 01, 02, 03
04, 05, 06, 07
10, 11, 12, 13
14, 15, 16, 17
APIC ID (logical mode)
00, 01, 02, 03
24, 25, 26, 27
10, 11, 12, 13
34, 35, 36, 37
155-xxx-xxx
Failed Active Memory
166-051-000
System Management: Failed. Unable to
communicate with ASM. It may be busy.
Run the test again.
Microprocessor
1
2
3
4
Microprocessor
1
2
3
4
latch test.
Action
1. Reseat the following components:
a. (Trained service technician only)
Microprocessor nn
b. Microprocessor tray
2. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. (Trained service technician only)
Microprocessor nn
b. (Trained service technician only)
Microprocessor tray
Note: Make sure you re-enable the memory in the
Configuration/Setup Utility program. See, "Memory
problems" on page 40
1. Reseat the memory card.
2. Replace the memory card.
1. Update the firmware (BIOS, service processor,
and diagnostics; see "Updating the firmware" on
page 133).
2. Run the diagnostic test again.
3. Correct other error conditions (including failed
systems-management tests and items that are
logged in the Remote Supervisor Adapter II
SlimLine system-error log) and retry.
4. Disconnect all server and option power cords
from the server, wait 30 seconds, reconnect the
power cords, and retry.
5. Reseat the Remote Supervisor Adapter II
SlimLine.
6. Replace the Remote Supervisor Adapter II
SlimLine.
67
Chapter 2. Diagnostics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 366 8863

Table of Contents