Mesh Network Components
No. of Spatial Streams
1
1
1
1
1
2
2
2
2
2
2
2
2
With two spatial streams, the MRC gain is halved, that is the MRC gain is reduced by 3 dB. This is because
Note
the system has 10 log (3/2 SS) instead of 10 log (3/1 SS). If there were to have been 3 SS with 3 RX, then
the MRC gain would have been zero.

Cisco 1500 Hazardous Location Certification

The standard AP1500 enclosure is a ruggedized, hardened enclosure that supports the NEMA 4X and IP67
standards for protection to keep out dust, damp and water.
Hazardous Certification (Class 1, Div 2, and Zone 2)
To operate in occasional hazardous environments, such as oil refineries, oil fields, drilling platforms, chemical
processing facilities, and open-pit mining, special certification is required and the certification is labeled as
Class 1, Div 2, or Zone 2.
OL-27593-01
11n MCS
Modulation
MCS 3
16QAM 1/2
MCS 4
16QAM 3/4
MCS 5
64QAM 2/3
MCS 6
64QAM 3/4
MCS 7
64QAM 5/6
MCS 8
BPSK 1/2
MCS 9
QPSK 1/2
MCS 10
QPSK 3/4
MCS 11
16QAM 1/2
MCS 12
16QAM 3/4
MCS 13
64QAM 2/3
MCS 14
64QAM 3/4
MCS 15
64QAM 5/6
Cisco Mesh Access Points, Design and Deployment Guide, Release 7.3
Cisco Outdoor Mesh Access Points
MRC Gain from 3 RXs (dB)
4.7
4.7
4.7
4.7
4.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7