Group Function - Hayward Pro Logic Installation Manual

Automation and chlorination
Hide thumbs Also See for Pro Logic:
Table of Contents

Advertisement

Flow Switch
Only applicable if the chlorinator function is enabled and/or the flow monitor feature is desired. The flow
switch cable plugs into the Pro Logic Control Center as shown in the diagram on page 12. Ensure that the
connector catch "snaps" in order to provide a reliable connection.
Turbo Cell
Only applicable if the chlorinator function is enabled. The Turbo Cell should be plugged in after the Pro Logic
cover panel is put back in place. Refer to page 12 for the location of the connector.
External Input Interlock
The External Input Interlock provides a means to force the filter pump or an Aux output off when certain conditions
exists. A normally open or normally closed on/off external device must be connected to the Pro Logic as shown
below. After properly configuring the Pro Logic (see Configuration), the filter pump and/or desired Aux will be
forced off when the device is active.
SPST External Switch
(either Normally Open or Normally Closed)
Hayward Aqua Rite Chlorinator
The Pro Logic can control one or more Hayward Aqua Rite chlorinators when additional sanitizing capacity is
required. A 4 wire connection is used to communicate to the Aqua Rite and can be wired up to 500' apart. Any
outdoor rated 4 conductor cable can be used. Refer to the wiring diagrams below for proper wiring connection to
the Aqua Rite. NOTE: There must be only 1 "primary" unit. All other Aqua Rite units must be configured as
"secondary".
Jumper Installed
For Primary
(Factory Default)
Aqua Rite
Pro Logic
(Primary)
NOTE: Primary/Secondary jumper is located underneath small circuit board.
GRN
4
YEL
3
Pro Logic
BLK
2
1
RED
GREEN
4
YELLOW
3
BLACK
2
Jumper Removed
RED
1
For Secondary(s)
Additional
Aqua Rite(s)
(if required)
Aqua Rite
(Secondary)
green
GRN
4
yellow
YEL
3
Aqua Rite
black
BLK
2
red
RED
1
21
5. Configuration Setup
After plumbing and wiring are complete, the Pro Logic MUST BE CONFIGURED before attempting to operate.
Configuration information is entered at the keypad and "tells" the Pro Logic what equipment is connected and how
each should be controlled.

Group Function

The latest version of the Pro Logic offers the ability to assign a Group function to a particular button. Instead of a
button controlling one particular function, the button can be programmed to initiate a sequence of commands that
are programmed in the Configuration Menu. For example, instead of the Lights button turning on and off the pool
light only, the button can be programmed to turn on the pool light, turn on the bug light, turn off the pool cleaner, turn
on and dim the patio lights, turn on the music, etc. all at the same time. This convenient feature is offered on all Aux
buttons, both Valve buttons and the Lights button. The Pro Logic can be programmed to control up to four groups.
Refer to this section when programming Group commands.
Before assigning and configuring all the desired functions and their control parameters, the group itself must be
configured. The options for controlling groups are Manual On/Off, Countdown Timer, and Timeclock. The group
will turn on and off based on this selection.
When setting up a Group function in the Configuration Menu, the first menu allows you to select the control
parameter (how the group is activated and de-activated) and the second menu allows you to select which Pro
Logic functions are to be controlled in the group.
A table of functions and their corresponding control parameters are listed below.
Function
Pool/Spa
Unaffected, Pool only, Spa only, or Spillover
Pool Filter
Unaffected, Off, On, High, Low, On (Lowest to Highest)
Lights
Unaffected, Off, or On
(standard relay)
Lights
Unaffected, Off, On (100%, 80%, 60%, 40%, or 20%)
(dimmer relay)
Lights
Unaffected, Off or On (10% to 100%)
(VSP relay)
Spa Filter
Unaffected, Off, On, High, Low, On (Lowest to Highest)
Aux1-14
Unaffected, Off
(s
tandard relay)
Aux1-14
Unaffected, Off, On (100%, 80%, 60%, 40%, or 20%)
(dimmer relay)
Aux1-14
Unaffected, Off or On (10% to 100%)
(VSP relay)
Valve3
Unaffected, Off or On
Valve4
Unaffected, Off or On
Spa Htr1 Set
Unaffected, Off, 65º-104ºF
Pool Htr1 Set
Unaffected, Off, 65º-104ºF
Spa Htr2 Set
Unaffected, Off, 65º-104ºF
Pool Htr2 Set
Unaffected, Off, 65º-104ºF
Spa Solar Set
Unaffected, Off, 65º-104ºF
Pool Solar Set
Unaffected, Off, 65º-104ºF
SuperChlr
Unaffected, Off, On
Control Parameter
or
On
22