Temperature Sensors
The Pro Logic utilizes 10K ohm thermistor type sensors. Three sensors (water temperature, air temperature and
solar or dual equipment spa temperature) are included. If the Pro Logic is being used to control a solar heating
system, the solar sensor is required. If dual equipment will be used, the dual equipment spa sensor (spa tempera-
ture for "Pool and Spa-Dual") is required. If both solar and dual equipment are desired, another temperature
sensor must be purchased separately. The sensors are provided with a 15 ft. cable. If a longer cable is required,
contact the Hayward service dept. (908-355-7995) for information on suitable cable types and splices. See
Temperature Sensors on page 6 for directions on installing sensors.
POOL/SPA
SENSOR
AIR
SENSOR
SOLAR
SENSOR
optional
DUAL EQUIPMENT
SPA SENSOR
optional
Wired Remote Display/Keypad
The Pro Logic main unit can connect to a maximum of 3 remote wired display/keypads. Wired display/keypads
must be ordered separately.
Use four conductor cable (typically phone cable) to connect the wired remote display/keypad with the Pro Logic
Control Center as shown below. The maximum wiring distance is 500ft. (160m). Note that the terminals on both
the Pro Logic main unit and the wired remote display/keypad are numbered: Connect 1 to 1, 2 to 2, etc. Refer to
diagram below.
Connect screw terminals
If multiple remote display/keypads are installed: Never connect more than 2 wires to any terminal block. Two
remotes can be wired back to the Pro Logic main unit or the second display/keypad (and third, if applicable) can
be "daisy chained" with one display/keypad wired to the next. The maximum wire run from the Pro Logic main unit
to the furthest remote display/keypad is 500 ft (160m).
"1" to "1", "2" to "2", etc.
Wired Remote
Display unit
4
3
2
1
500 ft max
19
Accessing the Configuration Menus
Configuring the Pro Logic requires that you navigate through the Configuration Menu and input various informa-
tion. For more detailed information about using the Pro Logic menu system, refer to the Operation Manual.
To access the Configuration Menus
Configuration
Press repeatedly until "Configuration Menu" is displayed
Menu-Locked
Press BOTH buttons SIMULTANEOUSLY for 5 seconds to unlock
Configuration
Move to configuration menu items
Menu-Unlocked
NOTE: The configuration menu automatically "locks" after 2 minutes of no buttons being pressed to
prevent unauthorized people from changing the control logic inadvertently and possibly damaging
the pool equipment or causing a "call back" to fix the configuration.
Configuration Menus
Each item needs to be programmed and may contain additional sub-menu items. Refer to the following pages for
information on programming.
Chlor. Config.
Chlor. Config.
Push to access Chlorinator option
+ to view/change
+ to view/change
Move to next configuration menu
Toggle between Chlorinator Enabled and Disabled (default)
Chlorinator
Chlorinator
Move to next menu item
Enabled
Enabled
Display
Display
Toggle between Display Salt (default) and Minerals
Salt
Salt
Move to previous/next configuration menu
Cell Type
Cell Type
Rotates between available Cell types
T-CELL-15
T-CELL-15
Move to next menu item
Chlorinator
Requires the use of a chlorinator cell and P-KIT sold separately. If the chlorinator is enabled, then
the cell and flow switch must also be installed and the Pro Logic will automatically chlorinate both the
pool and spa according to the desired output setting (see Settings Menu in the Operation manual). If
disabled (default), all displays relating to the chlorinator will be suppressed.
When the chlorinator is enabled, the Pro Logic will automatically detect and control any Aqua Rite(s)
that is installed in the system.
Display
Allows for the display of salt (default) or mineral values.
Cell Type Selection
The Cell Type Menu appears after "Display Salt/Minerals" in the Chlorinator Configuration Menu.
The options are T-CELL-15 (default), T-CELL-9, T-CELL-5 or T-CELL-3. Make the proper selection
based on the chlorinator cell that is used in your system. Refer to the information below.
"T-CELL-3" = T-CELL-3, GLX-CELL-3-W
"T-CELL-5" = GLX-CELL-5, GLX-CELL-5-W
"T-CELL-9" = T-CELL-9, GLX-CELL-9-W
"T-CELL-15" = T-CELL-15, GLX-CELL-15-W