Hayward Salt & Swim Owner's Manual

Hayward Salt & Swim Owner's Manual

Chlorine generator for inground swimming pools up to 25,000 gallons
Hide thumbs Also See for Salt & Swim:

Advertisement

Salt
Salt & & & & & Sw
Salt
Salt
Salt
Chlorine Generator for Inground
Swimming Pools up to 25,000 gallons
Owner's Manual
Owner's Manual
Owner's Manual
Owner's Manual
Owner's Manual
620 Division Street, Elizabeth, NJ 07207
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Sw
Sw i i i i i m m m m m
Sw
Sw
DIY-12
DIY-6
Hayward Pool Product
www.hayward.com
TM
Contents
Introduction....................1
Installation.................2-8
Operation..............12-14
Troubleshooting........15
Warranty.......................21
092463 RevA

Advertisement

Table of Contents
loading

Summary of Contents for Hayward Salt & Swim

  • Page 1 Swimming Pools up to 25,000 gallons Owner's Manual Owner's Manual Owner's Manual Owner's Manual Owner's Manual Contents Introduction....1 Installation....2-8 Operation....12-14 Troubleshooting..15 Warranty.......21 DIY-12 DIY-6 Hayward Pool Product 620 Division Street, Elizabeth, NJ 07207 www.hayward.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 2 When installing and using this electrical equipment, basic safety pre- cautions should always be followed, including the following: READ AND FOLLOW ALL • INSTRUCTIONS • TO REDUCE THE RISK OF DROWNING FROM HAIR AND BODY ENTRAPMENT, INSTALL A SUITABLY RATED SUCTION GUARD TO MATCH THE MAXIMUM FLOW RATE MARKED.
  • Page 3 Introduction Introduction Introduction Introduction Introduction The Salt & Swim is an automatic chlorine generation system for pool sanitization. It is designed for ingr It is designed for ingr ound swimming pools up to 25,000 gallons only ound swimming pools up to 25,000 gallons only .
  • Page 4 Installation Installation Installation Installation Installation Remove power to the pool filter pump before starting this installation. Installation must be performed in accordance with Local and NEC codes. The Control Box must be mounted a minimum of 10 ft. horizontal distance (or more, if local codes require) from the pool, within 3ft from a GFCI outlet, and within 15ft from where the Cell will be installed.
  • Page 5 The Cell Vessel is designed to install in either 1½" or 2" PVC pool plumbing. For pools using 1½" polypipe, you must use a Hayward DIY-POLYPIPE adapter kit. The Cell Vessel must be installed on a 10" run of straight pipe at the end of the return piping just before the water returns to the pool.
  • Page 6 With power removed to the pump and water drained from the pool plumbing, secure the Cutting Template to the location where the Cell Vessel will be installed. Note that the Cutting Template is the same width as the Cell Vessel. The entire Cutting Template must fit on the pipe otherwise the Cell Vessel will not fit.
  • Page 7 Position the Vessel in a manner where the Cell can be easily inserted and removed. Secure the Vessel to the cut pipe by tightening the Nuts as shown below. Handtighten the Nuts to stop, then continue 1/4 turn more using the included strap wrench. If the Inspection marks can be seen, the pipe has not been inserted far enough into the Cell Vessel.
  • Page 8 Connect and Fasten Cell Cap Connect and Fasten Cell Cap Connect and Fasten Cell Cap Connect and Fasten Cell Cap Connect and Fasten Cell Cap Slip the Cell Cap through the Retaining Nut as shown below. Plug the Cell Cap into the Cell and secure with the Retaining Nut.
  • Page 9 Flow Switch Calibration Procedure Flow Switch Calibration Procedure Flow Switch Calibration Procedure Flow Switch Calibration Procedure Flow Switch Calibration Procedure IMPOR IMPORT T T T T ANT IMPOR ANT: : : : : Before going any further, the pool water must be balanced and salt IMPOR IMPOR must be added to your pool.
  • Page 10 W W W W W ater Chemistry ater Chemistry ater Chemistry ater Chemistry ater Chemistry The table below summarizes the levels that are recommended by The Association of Pool and Spa Professionals (APSP). It is important to maintain these levels in order to prevent corrosion or scaling and to ensure maximum performance from your Salt &...
  • Page 11 Salt Level Salt Level Salt Level Salt Level Salt Level Use the chart on page 10 to determine how much salt in pounds or (Kgs) need to be added to reach the recommended levels. Use the equations below (measure- ments are in feet/gallons and meters/liters) if pool size is unknown. Liters Gallons (pool size in meters)
  • Page 12 POUNDS and (Kg) of SALT NEEDED FOR 3200PPM Gallons and (Liters) of Pool Water Current salt level 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 25,000 8,000 (30,000) (37,500) (45000) (52,500) (60,000) (67,500) (75,000) (82,500) (90,000) (93,500) (97) (194) (121) (145) (170) (218)
  • Page 14 Operation Operation Operation Operation Operation Controls Controls Controls Controls Controls The main controls and indicators are shown below. Illuminates when Cell has reached the end of its expected life. When this LED indicator is illuminated, there is a problem with the unit.
  • Page 15 Operation Operation Operation Operation Operation The Salt & Swim does not have an ON/OFF switch . The unit is designed to be plugged into a GFCI rated outlet at all times. There should be no need to remove power from the Salt & Swim unless pool components are being serviced or the pool will be closed.
  • Page 16 Maintaining the Salt & Swim System The replaceable Cell uses the same electronic self cleaning technology as the popular Hayward Turbo Cell. In most cases this self cleaning action will keep the Cell working at optimum efficiency. In areas where water is hard (high mineral content) and in pools where the water chemistry has been allowed to get "out of...
  • Page 17 The Salt & Swim's various LEDs show the operation status as well as alert the user to any problems that may have occurred. Some indications may require a combi- nation of LEDs to illuminate. To aid in interpreting these indications, Hayward has created an interactive tool located at www.hayward.com. Use this tool and the information below to identify and correct problems that may arise.
  • Page 18 If the condition persists, remove the Cell from the Vessel and check that the flow switch is free to move in both directions. Refer to the diagram below. Flow Switch 5. 5. 5. 5. 5. CELL LIFE LOW LED illuminated CELL LIFE LOW LED illuminated CELL LIFE LOW LED illuminated CELL LIFE LOW LED illuminated...
  • Page 19 4. Inspect the Cell Vessel and verify the Cell plates are fully covered by moving water. 5. Contact Hayward Technical Service. 1. Recycle power to the Salt & Swim by unplugging the linecord for two minutes and then plugging it back in.
  • Page 23 To obtain warranty service or repair, please contact the place of purchase or the nearest Hayward authorized warranty service center. For more information on authorized service centers please contact the Hayward Technical Service Support Center (61 Whitecap Road, North Kingstown RI, 02852) or visit the Hayward website at www.hayward.com.
  • Page 24 Copyright © 2012 Hayward Inc.

This manual is also suitable for:

Salt & swim™ 3c

Table of Contents