Optional Remote Controls
Hayward offers a variety of wired and wireless remote control options for the Pro Logic. Each model gives you
the ability to control your pool's functions from a remote location, away from the Control Center.
Wired Remote Controls
Up to 3 wired remote controls can be installed. See "Electrical Wiring" (page 19) for instructions on running the
cable from the Pro Logic main unit to the remote control. Also refer to the remote's installation instructions for more
information.
AQL2-Wx-PS-x (x=4,8, or 16)
The AQL2-Wx-PS-x is a wall mounted display/keypad which must be mounted indoors or in a weather protected
area (rain should never hit the unit). Note that the number of outputs on the remote ("4", "8" or "16") must match
the outputs on the Pro Logic main control unit. This remote control is intended to mount on to a standard electrical
utility box (same box as a triple light switch, ideal for new construction) or can be mounted directly onto any wall
surface. When selecting a location, note that the wire to the Pro Logic main unit must be less than 500' long.
AQL-SS-6B-x, AQL-SS-D-x (x=W or B for White or Black)
The AQL-SS-6B and AQL-SS-D are double insulated, waterproof devices which are intended for installation at
the water's edge. The remote controls come with an attached 150' cable and are typically installed at the tile-line
of the spa wall, or in the deck, within arm's reach of a pool/spa occupant.
Wireless Remote Controls
A single Base Station must be installed on the Pro Logic in order to use any of the Hayward wireless remote
controls. There is no limit on the number of wireless remotes that can used. The maximum distance between
wireless remotes and the base station on the Pro Logic main control unit is 400 feet (120m) line of sight or 200 feet
(60m) through walls, etc. If in doubt about the distance, test operation before installing the remote. All wireless
models require the user to run the "Teach Wireless" routine in the Settings Menu. This information can be found in
the Pro Logic Operation Manual and the owner's manual of each remote.
AQL2-Wx-RF-PS-x (x=4,8, or 16)
The AQL2-Wx-RF-PS-x are wall mounted wireless controls designed to be mounted indoors. These remote
controls come with a wall mounted power supply.
AQL2-Tx-RF-PS-x (x=4,8, or 16)
The AQL2-Tx-RF-PS-x are portable battery operated remote controls designed to be used in a weather pro-
tected area (rain should never hit the unit). The AQL2-Tx-RF-PS-x comes with a wall mounted power supply for
recharging the built-in batteries.
AQL2-SS-RF, AQL2-POD
The AQL2-SS-RF and AQL2-POD are waterproof portable remote controls that are designed to be used in and
around the pool/spa area. These units float and can be left in the pool/spa water for easy access.

Optional Base Station

Use the AQL2-BASE-RF for all AQL2 wireless remote controls. To install the base station, remove the knockout
on the upper left side of the Pro Logic main control unit, insert the base station, and then tighten the nut from the
inside. Also refer to the Base Station manual and the diagram on page 20.

Optional Valve Actuators

For optional actuators supplied with the Pro Logic—note that the internal cams in the actuator may also have to be
adjusted depending on the way the actuator is mounted on the valve and the desired valve action.
RETURN
OUT
IN
(Common)
SUCTION
OUT
IN
IN
OUT
(Common)
7
position other than "pool only", or for the first 3 minutes after solar turns on (allows air in the solar
panels to be purged). Interlock is not available for solar, low speed filter pump, dimmer, group, super
chlorinate or pH dispense functions.
Aux1 Group
The Aux1 Group function allows the user to perform multiple tasks with a single push of the "Aux1"
button. When setting up a Group function, refer to page 22 for specific programming information.
There are two Group menus; the first menu determines how the group command will be initiated
(Manual On/Off, Countdown Timer, or Timeclock) and the second menu selects the desired functions
and their respective control parameters.
When activating Group functions, be aware that the most recent Group function that is initiated will
override any previous Group function.
Aux1 External Input Interlock
When Aux1 External Input Interlock is enabled, the Aux1 output will be forced off when the external
input is active. This will have precedence over freeze protection. Aux1 External Input Interlock is not
available for solar, low speed filter pump, dimmer, group, super chlorinate, or pH dispense functions.
Aux1 Freeze Protection
This function protects the pool, plumbing, and equipment against freeze damage. If Freeze Protection
is enabled and the AIR temperature sensor falls below the selected freeze protection temperature, the
Pro Logic will turn on the aux relay to circulate the water. IMPORTANT: this only enables operation
of the AUX output during freeze--see the "Filter Pump Config." menu to enable freeze protection for
the main circulation system. Freeze Protection is not available for low speed filter pump, dimmer,
group, super chlorinate or pH dispense functions.
Aux1 Pump Speed
This is the speed of the filter pump when the Aux1 output is on. The default selection is "Settings
Menu". This is the speed of the pump that has been selected in the Settings Menu for normal filter
operation. If an alternate speed is desired when the Aux1 output is on, push "+" or "-" and select from
"Lowest" to "Highest" in 5% increments.
PL-PS-8-V models only: Aux3 - Aux7 only
PL-PS-16-V models only: Aux7 - Aux14 only
Aux7 Config.
Push to access Virtual Aux options
+ to view/change
Move to previous/next configuration menu
Aux7 Name
Rotates between all available names
Cleaner
Move to next menu item
Aux7 Relay
Toggle between Standard (default) and ColorLogic (must be detected)
Standard
Move to next menu item or previous/next configuration menu
Aux7 Function
Rotates between Super Chlorinate,
Group
Move to next menu item
Aux7 Group
Rotates between Manual On/Off (default),Countdown Timer and Timeclock
Timer: None(Manual)
Move to next configuration menu item
Aux7 Group
Options available depend on the function that is selected
Filter: Unaffected
Move to previous/next menu item or next configuration menu
For more information on the Group function, refer to page 22. If neither Super Chlorinate, ColorLogic or a Group
can be assigned to a Virtual Aux button, the following will be displayed:
No Virtual
Functions Available