Hayward Pro Logic Installation Manual page 21

Automation and chlorination
Hide thumbs Also See for Pro Logic:
Table of Contents

Advertisement

Chemistry Config.
Press to access Chemistry Config. Wizard
Wizard + to enter
Move to previous/next menu item
Chemistry Configuration Wizard
Requires use of the optional AQL-CHEM Sensing Kit. Following the steps of the Chemistry Config.
Wizard will set up the AQL-CHEM to sense ORP and pH levels and, if the chlorination function is
used, can configure the Pro Logic to generate the correct amount of chlorine to properly sanitize the
pool. Refer to the AQL-CHEM manual for more detailed information.
Pool/Spa Config.
Push to access Pool/Spa options
+ to view/change
Move to previous/next configuration menu
Rotates between Pool and Spa-Std
Pool/Spa Setup
Pool Only, and Spa Only options
Pool and Spa-Std
Move to next menu item
if "Pool and Spa-Dual" is selected
Heaters
Toggle between Htr1=Spa, Htr2=Pool (default) and Shared Heaters
Htr1=Spa,Htr2=Pool
Move to next menu item
if "Pool and Spa-Std" is selected
Spa - CountDn
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default is 4:00))
00:30
Move to next menu item
if "Pool and Spa-Std or Dual" is selected
Spa Spillover
Toggle between Enabled and Disabled
Enabled
Move to next menu item or previous/next configuration menu
if "Pool and Spa-Std or Dual" is
selected and if "Spa Spillover" is enabled
Filter Operation
Toggle between Pool Only
Spa Spillover
Move to previous/next configuration menu
if "Pool Only" or "Spa Only" is selected
V1=Aux1, V2=Aux2
Toggle between Enabled and Disabled (default)
Disabled
Move to previous/next configuration menu
if "Pool and Spa-Std" is selected
Filter Off Valve
Toggle between Enabled
Change: Enabled
Move to previous/next configuration menu
Pool/Spa Setup
If "Pool Only" or "Spa Only" are selected, then the pool/spa valves are not needed and pushing the
POOL/SPA button on the display/keypad will have no effect. If "Pool and Spa-Std" is selected, then
the pool/spa suction and return valve actuators should be connected to the Pro Logic. Pressing the
POOL/SPA button on the display/keypad will allow the homeowner to alternate between pool and spa
operation. If "Pool and Spa-Dual" is selected, then only the Pool/Spa return valve actuator should be
connected to the Pro Logic.
Heaters
This menu will only appear if Pool/Spa setup is set to "Pool and Spa-Dual". This allows the heater(s)
to either be shared between the pool and spa ("Shared" selected) or for Heater1 to be dedicated to the
spa and Heater2 to be dedicated to the pool ("Htr1=Spa, Htr2=Pool" selected).
Spa CountDn
This menu will appear only if Pool/Spa Setup is set to "Pool and Spa-Std". This setting is the time,
after you manually switch the Pool/Spa valves to "Spa Only", until the Pro Logic automatically
returns the valves to their previous positions. It is programmed in increments of 5 minutes, from
"Manual On/Off" (0 minutes) to
Spa Spillover
When spa spillover is "Enabled" and "Pool and Spa-Std", the homeowner will be able to rotate
through "Pool Only" (both suction and return valves switched to pool), "Spa Only" (both suction and
return valves switched to spa) and "Spillover" (suction valve switched to pool and return valve
(default)
, Pool and Spa-Dual,
(default)
Spa Spillover
(default)
and Spa Spillover options
(default)
and Disabled
"21:00" (21 hours).
The filter is forced on during this time period.
25
STA-RITE Heater
1. Turn power off to heater.
2. Remove upper jacket and open the control box.
3. Remove the jumper for the "fireman's switch.
4. Wire to the Pro Logic using wire rated for 105°C minimum.
Fireman's
Switch
Operating
'Control
Terminal
Board
STA-RITE
Hayward Variable Speed Pump (VSP) Wiring and Address Setting
Refer to your TriStar or EcoStar manual(s) for proper low voltage communication wiring between the Pro Logic
and the Hayward Variable Speed Pump.
A pump address must be configured for each VSP used in the system. This address is entered into the VSP's
configuration menu. Refer to the table below to determine which address to use for your specific pump and Pro
Logic. Select the proper address based on which output will be used and the model VSP you are configuring.
Pro Logic Output
This is the output used to control the VSP.
Note that the VSP should be wired to this
output's corresponding relay.
FILTER - all Pro Logic models
AUX1 - all Pro Logic models
Dual Equipment Spa Filter - all models
LIGHTS - all Pro Logic models
A
UX
2 - all Pro Logic models
A
UX
3-A
UX
6 - PS8 & PS16 models
A
UX
7-A
UX
14 - PS16 models
VSP Address
This is the name that should be selected
under "Set COMM bus address" (EcoStar)
or "*H.Comm ADDR." (TriStar) within the
VSP's Configuration Menu.
"001" - Tristar
"Pool Filter" - EcoStar
"002" - Tristar
"
Aux1 / Spa Filter
" - EcoStar
"Lights Button" - EcoStar only
Aux2-Aux14 - EcoStar only
(use same as Pro Logic Output)
18