Disassembly and Assembly
3.2.2.6 Toner End Sensor Removal
1.
Open the top cover. Remove the imaging cartridge. Cover the imaging cartridge to protect it
from light or place it in a dark area.
2.
Remove the optical unit. (Refer to Section 3.2.2.4.)
3.
Disconnect tabs for the toner end sensor and remove the toner end sensor.
4.
Disconnect connector for the toner end sensor.
3-14
Figure 3-16. Toner End Sensor Removal
EPL-N1200 Service Manual
Rev. A