LYNXR-2 Series Installation and Setup Guide
System Operation

System Displays

Display
PC
Remote Phone Control feature is active (Appears in place of the clock).
PH
System Speaker Phone mode is active (Appears in place of the clock).
AC
AC power is present. If not displayed, the system is operating on backup battery power.
ALARM
System is armed and an intrusion has been detected (also appears during a
fire alarm or audible emergency alarm). Accompanied by the protection zone
that is in alarm.
AWAY
All burglary zones, interior and perimeter, are armed.
BYPASS
One or more burglary protection zones have been bypassed.
CHIME
Chime feature is activate
FAULT
A malfunction is discovered in the system; or an open is detected in a fire zone; or a
fault in a day/night burglary zone is discovered during a disarmed period.
Accompanied by a display of the zone number in trouble.
FIRE
A fire alarm or fire fault is present. Accompanied by a display of the zone that
is in alarm
LOW BAT
Low battery condition in a wireless sensor (if zone number is displayed) or low system
battery (if no zone number is displayed). If 00 is displayed, a wireless keypad has a low
battery condition.
INSTANT
Entry delay is turned off.
MESSAGE
A message has been recorded and has not yet been played back.
REC
The system is in Recording mode.
STAY
Perimeter Burglary zones, such as protected windows and doors, are armed
TEST
System is in Test mode.
UL
UL
UL
UL
Audio alarm verification has not been evaluated by UL.
Audio Alarm Verification (Two-Way Voice Feature)
This feature allows the central station operator to listen, talk to or conduct a two-way conversation with an
individual(s) at the premises. It also assists the operator in gathering information about the nature and
location of the alarm that may be helpful in responding to police and fire departments. All LYNXR-2 Series
control panels are capable of supporting the Two-Way Voice feature. The LYNXR-2 Series does not make
system announcements when the Two-Way voice feature is active.
Activation
Fire and CO alarms will not trigger an AAV session. A new Fire or CO alarm will end an AAV session that is
in progress.
The LYNXR-2 Series sends the "alarm message" followed by a "Listen-in-to-Follow message" (Contact ID®
code 606) to the Central Station. The Listen-in-to-Follow message causes the Central Station's digital
receiver to temporarily hold the phone line for approximately 1-minute. When the LYNXR-2 Series receives
the "kissoff" from the central station, indicating that the alarm message has been received, the Two-Way
Voice (AAV) feature is activated in the (default) "Listen Mode" and sirens and keypad sounds are
discontinued. The LYNXR-2 Series transmits a beep acknowledgment to the Central Station, once per
second. The beep alternates between two tones and indicates that the LYNXR-2 Series is waiting for a
session command from the Central Station operator. Once a command is issued the beep acknowledgement
is discontinued, however, if a command is not issued within two minutes the system will "time out" and the
call will be terminated.