Remote Phone Control Keypad Functions
To remotely disarm system:
To remotely arm in AWAY mode:
To remotely arm in STAY mode:
To remotely arm in AWAY or STAY with no delay:
To remotely activate X10 devices 1-6:
To remotely activate X10 devices 7 & 8:
To remotely deactivate X10 devices 1-6:
To remotely deactivate X10 devices 7 & 8:
To remotely Bypass zones:
To remotely activate Forced Bypass:
To remotely check system status:
To end remote phone control session:
Powerline Carrier Devices (e.g. X10 devices)
If Powerline Carrier Devices are used, two keypad entries available to the user are included. They
can manually activate or deactivate the device(s) for starting or stopping some action, such as
turning lights on or off, etc.
These keypad entries are:
Security Code* + [#] + [4] + Device # activates (starts) that device.
Security Code* + [#] + [7] + Device # de-activates (stops) that device.
*Code is required for devices 7 and 8. Code is not required for devices 1-6.
Exit Error Alarm Displays
The system will display the following if programmed in Field *59.
Display
CA
will appear along with a zone indication if an exit or interior zone contained a
fault during closing at the time the exit delay ended (e.g., exit door left open),
but the system was disarmed during the entry delay time. The alarm
sounder and keypad sound continuously, but stop when the system is disarmed.
No message will be transmitted to the central station.
EA
will appear along with a zone indication if an exit or interior zone contained a
fault during closing at the time the exit delay ended, but the system was NOT
disarmed during the entry delay time. The alarm sounder and keypad
sound continuously until the system is disarmed (or timeout occurs). An Exit
Alarm message is sent to the central station. OR
if an alarm from an exit or interior zone occurs within two minutes after the
end of an exit delay
Entering a second OFF sequence (Code +
+ [1]
+ [2]
+ [3]
[#] + [4] + (2-digit) device no.
+ [#] + [4] + (2-digit) device no.
[#] + [7] + (2-digit) device no.
+ [6] + zone no.
+ [6] + [#]
[✻]
Hang Up or enter
Meaning
OFF
) will clear the display.
- 57 -
LYNXR-2 Series Installation and Setup Guide
System Operation
+ [2] or [3] + [0]
+ [#] + [7] + (2-digit) device no.
+ [9]