LYNXR-2 Series Installation and Setup Guide
Data Field Descriptions
✻75
RF Transmitter Low Battery
Restore Report Code
(See notes above)
✻76
Test Restore Report Code
(See notes above)
To ensure that the LYNXR-2 Series properly transmits its reports to the Central Station via the proper channel you must
program a Primary Phone Number in Field *41 and/or activate/deactivate the LRR/IP Communications Module in Field *55.
The 15-Second Dialer Delay (Burglary), programmed in Field in *50 is independent of the delay selected in Field *77 and
applies to both telephone and communications device.
DYNAMIC SIGNALING DELAY/DYNAMIC SIGNALING PRIORITY FIELD
Two report channels are used by the LYNXR-2 Series to support the LRR/IP communications device and
dynamic signaling. For the primary channel the device can communicate via AlarmNet GSM/IP or Cellular
communications devices. Secondary phone is not affected by dynamic signaling scheme. Two programming
options are used to define dynamic signaling behavior. Field *55 is used to enable/disable the LRR/IP
communications device and allows it to supervise the communications module. The two-digit option
programmed in Field *77 defines how dynamic signaling will function. The Dynamic signaling options are
shown as follows
:
Reporting Option
Primary Phone only
Report is sent to Primary phone with No Dynamic Signaling
Delay
LRR/IP only
Report sent to communications device with No Delay
Redundant reports to both channels
Report independently goes to the Primary phone and LRR/IP
communications device with No Delay
Primary Phone is the preferred channel
First report is sent to the primary phone. If primary phone
fails to deliver report within the delay window defined in *77
all following reports go to both primary phone and
communications device with no delay. When report goes
through the primary phone, the control stops reporting to
communications device.
Note: The delay must be set to at least 30 seconds if Remote
Phone Control and/or AAV is enabled.
LRR/IP is the preferred channel
First report is sent to the communications device. If device
fails to deliver report within to deliver report within the time
window defined in *77 all following reports go to both LRR/IP
device and primary phone with no delay. When report goes
through the LRR/IP device, the control stops reporting to
primary phone.
Sent when a transmitter that previously sent in a "low battery"
message has sent a message indicating it no longer has a low battery
condition.
Sent when the test mode is exited. A restore code entered here will
cause a restore message to be sent when Test mode is exited.
Note: The LYNXR-2SIA validates the data entered in this field. If the
selection is not valid the control will emit a single long beep
indicating that the selection has been rejected. The control
replaces the selection with the default value "10", which is
displayed on the keypad, and advances to the next field.
Enable/Disable
Dynamic Signaling Delay/Dynamic Signaling
Device (Field *55)
0 = Telco Line only
1st Entry
(no Radio)
* = enter a delay for the first entry
2nd Entry
0 = Primary phone only
3 = LRR/IP (Digital
1st Entry
Communication
* = enter any non zero digit as a first entry
only) (no Telco
2nd Entry
Line) OR
2 = LRR/IP reporting only
5 = LRR/IP (Digital
Communication
w/Voice
Capabilities)
(no Telco Line)
1 = LRR/IP (Digital
1st Entry
Communication
0 = Redundant reporting on dialer and
only) and Telco
communication device
Line
2nd Entry
* = enter any number as a second entry
1 = LRR/IP (Digital
1st Entry
Communication
* = enter a delay for the first entry
only) and Telco
2nd Entry
Line
0 = Primary Dialer is the preferred channel
1 = LRR/IP (Digital
1st Entry
Communication
* = Enter any delay for the first entry
only) and Telco
2nd Entry
Line
1 = LRR/IP is the preferred channel
- 32 -
✻
77
(Field *77)
Need help?