LYNXR-2 Series Installation and Setup Guide
✻ 83 Enhanced Sequential Mode
A 02
Zone Number
Enter 2-digit zone number.
[✻] = continue; system searches for zones not
yet entered (for zones 2 through 25 a
zone type must be entered), then
advances to ENROLL SERIAL NUMBER
prompt "1b"
00 = exit Sequential mode
zz
IA
IA
LC
Enroll Mode
0 = advance to next zone to be enrolled
1 = enter now and proceed to SERIAL
NUMBER prompt (1b). For 4 button keys
(zones 26-29, 30-33, 34-37, & 38-41) the serial
number will be enrolled to all four buttons.
If enrolling a key, the panel will emit a long
beep when entering a 1 to indicate that the
present key set up is invalid.
2 = copy the previous serial number entry
from the buffer.
3 = view existing serial number.
4 = copy the 4 button key template that has
been set in zone numbers 26-29 (all zone
parameters except serial numbers). (Only
valid on zones 30-33, 34-37, & 38-41 that
do not have serial numbers enrolled.)
9 = delete existing serial. Go to the (1A)
prompt. For 4-button key, zones 26-29, 30-
33, 34-37, & 38-41 have serial numbers.
Delete all four at one time.
[✻] = advance to next zone to be enrolled
[#] = return to previous prompt (A)
Enter the 2-digit zone number of the first transmitter to have its serial number
entered. The system will announce the Voice Descriptor for the selected zone number,
if it is programmed.
Press [✻] to continue. Starting with this zone number, the system will search for the
first transmitter that has all of the following attributes pre-programmed in ✻56
ENHANCED ZONE PROGRAMMING:
The appropriate input type was selected in ✻56 (RF, UR, or BR programmed)
a)
The appropriate loop number was selected in ✻56.
b)
c)
No serial number has been programmed
d)
Zone type
If the first zone number entered does not have one or more of the above attributes,
the system will search its database for the first zone that does, and will display it at
the enroll SERIAL NUMBER prompt (1b).
Enter 00 to exit. Prompt "83" blinks, indicating the mode is inactive.
Note: Two exceptions to the requirement above exist for keys. Four zone button type
devices (zone numbers 26, 30, 34, and 38) will be stopped only if there are no
serial numbers enrolled in all 4 zones of the key, regardless of the attributes that
have been entered. In addition, zone types are not required to be present. In this
case, 1A, Option 4 must be selected prior to "Learn".
If "L" is displayed, the serial number for this transmitter has already been entered,
however, it may still be confirmed, viewed or deleted. If the transmitter's serial
number has not been previously entered, you may enter the enroll serial number
mode (1A) by entering "1". Enter "2" to copy the last serial number that was entered.
A serial number must be entered in order to be copied. If no serial is stored in the
buffer and a copy is attempted the panel will emit a long beep indicating an invalid
operation.
If the transmitter's serial number has been previously entered, you may, view the
present serial number by entering "3". If view is selected each digit will be re-
displayed, and the keypad will beep once for digits 1-6, and three times for the last
digit. Once the serial number has been entered by either selecting a "1" or a "2", you
will return to this prompt with the "L" on the display. The serial number/loop number
combination that was entered can be confirmed by getting two transmissions (fault
and restore) from the RF or UR device or one transmission from the BR device. If a
transmission is received that matches the serial number and loop number entered,
the system will announce the Voice Descriptor for the loop followed by three beeps,
and a "C" will be displayed indicating that the received serial number and loop
number transmission has been confirmed to match. No further transmissions will be
received. When confirming a 4 button key, only the serial number is confirmed, since
it assumed that all loops are used. Pressing any key will allow a confirmation.
*Long beep indicates illegal entries, or duplicate serial number/loop entry*
When the last zone has been entered, the display will remain on that zone. To exit
this mode and return to data field program mode, enter 00 at the ZONE NUMBER
prompt.
When all zones have been programmed, test each zone using the system's Test mode.
Do not use the Transmitter ID Sniffer mode for this, since it will only check for
transmission of one zone on a particular transmitter, and not the zones assigned to
each additional loop.
For Zones 26-29, 30-33, 34-37, and 38-41 any loop can be used for RF enrollment. If
enrolling via RF, it will be confirmed without additional transmissions.
Notes:
(1) A valid template or key has 4 existing zones, each with a zone type, unique loop
number.
(2) Option 2 is not applicable for 4 button key zones 26-29, 30-33, 34-37, & 38-41.
(3) If the display automatically returns to "1A" rather than "1b" the configuration of the key
is not valid. At that point copy template, skip, or return are the only legal entries.
(4) If option 3 or 9 is selected, the serial number can be viewed or deleted but only if "L"
is displayed. If the "L" is not displayed the panel will emit a long beep.
(5) If option 4 is selected template acceptance is indicated by two beeps after copying. A
single long beep, emitted when copying indicates the template is not valid.