LYNXR-ISIA Installation and Setup Guide
System Operation

System Displays

Display
PC
Remote Phone Control feature is active (Appears in place of the clock).
PH
System Speaker Phone mode is active (Appears in place of the clock).
AC
AC power is present. If not displayed, the system is operating on backup battery power.
ALARM
System is armed and an intrusion has been detected (also appears during a
fire alarm or audible emergency alarm). Accompanied by the protection zone
that is in alarm.
AWAY
All burglary zones, interior and perimeter, are armed.
BYPASS
One or more burglary protection zones have been bypassed.
CHIME
Chime feature is activate
FAULT
A malfunction is discovered in the system; or an open is detected in a fire zone; or a
fault in a day/night burglary zone is discovered during a disarmed period.
Accompanied by a display of the zone number in trouble.
FIRE
A fire alarm or fire fault is present. Accompanied by a display of the zone that
is in alarm
LOW BAT
Low battery condition in a wireless sensor (if zone number is displayed) or low system
battery (if no zone number is displayed). If 00 is displayed, a wireless keypad has a low
battery condition.
INSTANT
Entry delay is turned off.
MESSAGE
A message has been recorded and has not yet been played back.
REC
The system is in Recording mode.
STAY
Perimeter Burglary zones, such as protected windows and doors, are armed
TEST
System is in Test mode.