LYNXR-2 Series Installation and Setup Guide
Data Field Descriptions
✻29
Daylight Savings Time Start/
End Month
0 = do not display the time
1 = display the time
✻30
Daylight Savings Time Start/
End week
0 = disable
1 = first weekend of month
2 = second weekend
3 = third weekend
4 = fourth weekend
5 = last weekend
6 = next to last
7 = 3
rd
from last
✻31
Single Alarm Sounding Per Zone
(per armed period)
LYNXR-2 SELECTIONS
0 = no limit on alarm sounding per zone
1 = limit alarm sounding to once per arming period for a
given zone
LYNXR-2SIA SELECTIONS
0 = Alarm Sounding Per Zone will be the same as the
Swinger Shutdown" set in field *92
1 = limit alarm sounding to once per arming period for a
given zone
✻32
Sounder Timeout
0 = yes, sounder timeout after time programmed in field
1 = no sounder timeout; continue sounding until manually
turned off
✻33
Alarm Bell Timeout
0 = No timeout
1 = 4 minutes
2 = 8 minutes
3 = 12 minutes
4 = 16 minutes
Fields
34–
36: Fields *34, *35 and *36 are used to program different options in the LYNXR-2 and LYNXR-
2SIA controls. Please be sure that you use the correct field for the control being installed.
Note: The LYNXR-2 SIA control validates the data entered in fields *34 - *36. If the selection is not valid the control will emit a
single long beep indicating that the selection has been rejected. The control replaces the selection with the default
value which is displayed on the keypad.
✻34
Exit Delay
LYNXR-2 SELECTIONS
00-99 = exit delay time in seconds
LYNXR-2SIA SELECTIONS
Entries from 45-97
Entered Value
Delay in Seconds
45-96
45-96
97
120
Enter # + 10 for 10, # + 11 for 11, and # + 12 for 12.
Enter the appropriate start and end weekend of the month.
This field applies only to burglary zones (zone response types
1-5, 10), and affects long range radio reporting but does not
affect central station reporting.
Note: This field applies only to the bell and does not affect keypad
sounds.
UL installations: must be 0 (no limit)
This Control complies with NFPA requirements for temporal
pulse sounding of fire and carbon monoxide (CO) notification
33
appliances.
Temporal pulse sounding for a fire alarm consists of the
following: 3 pulses – pause – 3 pulses – pause – 3 pulses. . .
Temporal pulse sounding for a CO alarm consists of the
following: 4 pulses – pause – 4 pulses – pause – 4 pulses –
pause. . .
This field determines whether the external sounder will shut
off after time allowed, or continue until manually turned off.
UL installations: must be set for a minimum of 4 min (option 1)
The system will wait the time entered before sounding an
alarm if the exit door is left open after the system has been
armed.
UL installations: must be set for a maximum of 60 seconds
Note: The LYNXR-2SIA control validates the data entered in this field. If
the selection is not valid the control will emit a single long beep
indicating that the selection has been rejected. The control replaces
the selection with the default value "60", which is displayed on the
keypad, and advances to the next field.
SIA: Exit Delay must be set to a minimum of 45 seconds.