LYNXR-2 Series Installation and Setup Guide
✻ 80 Device Programming Menu Mode
zt
E
Start Zone Type
01-58 = zone type to start this device action
(select only those that are applicable
00 = zone type not used for this device
[✻] = continue
[#] = return to previous prompt
zl
F
Stop Zone List
1-3 = zone list to stop this device action
0 = zone list not used
[✻] = continue
[#] = return to previous prompt
zt
1A
Stop Zone Type
01-58 = zone type to stop this device action
(select only those that are applicable
00 = zone type not used for this device
[✻] = continue
[#] = return to previous prompt
If a zone type or system operation will be used to start the device action, enter the
appropriate 2-digit code for the device being programmed (see table that follows).
Choices for zone types
00 = Not Used
01 = Entry/Exit #1
02 = Entry/Exit #2
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24 Hr Silent
Choices for system operation
20 = Arming–Stay
21 = Arming–Away
22 = Disarm. (Code + OFF)
31 = End of Exit Time
32 = Start of Entry Time
33 = Any Alarm (except ZT 08,
09, 14 or 16)
36 = At Bell Timeout**
** Or at Disarming (which ever occurs earlier)
SIA ZT 16 must be used in SIA fire applications.
If a zone list will be used to STOP, or restore, the device action, enter the zone list
number 1, 2, or 3 (to be programmed in ✻81 mode). If not used, enter "0".
If a zone type or system operation will be used to STOP the device action, enter the
appropriate 2-digit code (see the "ZT" choices listed above). If not, enter 00. The
display then returns to the DEVICE NUMBER prompt (A) so that you can enter the
next device number to be programmed, or enter [0][0] to end device programming
- 44 -
07 = 24 Hr Audible
08 = 24 Hr Aux
09 = Fire without verification
10 = Interior w/Delay
14 = Carbon Monoxide
16 = Fire with verification
24 = Silent Burglary
38 = Chime
52 = Kissoff
39 = Any Fire Alarm
40 = Bypassing
42 = System Battery Low
43 = Communications Failure
58 = Duress
Need help?