The following explains these prompts in detail. The left two columns identify the prompts and list the
available entries. The right-most column provides a further explanation of the entries.
Note: Entering a number other than one specified will give unpredictable results.
ZT16 is only available on the LYNXR-2SIA version of the control panel.
80
Powerline Carrier Device
Programming
0 = exit mode
1 = enter mode
A
01
Device Number
01-08 = X10 device number to be
programmed
09-16 = Multi-mode (e-mail) event triggers
[✻] = continue
00 = exit Device Programming mode
b
aa
Device Action
0 = No response
1 = Close for 2 seconds
2 = Close and Stay Closed
3 = Continuous Pulse on & off (1 sec ON, 1
sec OFF)
[✻] = continue
[#] = return to previous prompt
et
C
Start Event Type
0 = Not used
1 = Alarm
2 = Fault
3 = Trouble
[✻] = continue
[#] = return to previous prompt
d
zl
Start Zone List
1-3 = zone list number (to be programmed in
field ✱81)
0 = zone list not used for this device
[✻] = continue
[#] = return to previous prompt
✻ 80 Device Programming Menu Mode
Entering "0" exits mode, upon which this prompt blinks, indicating that the mode is
inactive.
Entering "1" advances to the next prompt below.
Enter device numbers as 2-digit entries.
Enter the 1-digit action (0-3) for the device being programmed (current action is
displayed).
Notes: (1) If "3" is entered (pulse), only up to 3 different devices can be pulsed if one of
the devices is a siren/horn (X10 Powerhouse Security model SH10A). In
addition, the siren/horn cannot be manually activated using the lights
on/lights off keypad commands.
(2) If using an X10 Powerhouse Security SH10A siren, you must:
• use device action "3."
• change the device action default to "3" (if using default table 2 or 4).
Enter the 1-digit event type (0-3) to activate the device being programmed. A zone list
must be used in conjunction with an event. If a zone type/system operation is to be
used instead of an event, enter "0".
If a zone list will be used to start the device action, enter the zone list number at this
prompt.