LYNXR-2 Series Installation and Setup Guide
Connecting/Configuring Communication Modules
AlarmNet 7845GSM, 7845i-GSM*, 7845i-ENT, 7845i or 7847i-E* Communications Device
The 7845i-ENT and 7845i cannot be used for installations requiring 24-hour standby.

1. Connect the 4-wire communications cable to the LRR/IP Communications port on the LYNXR-2 Series.
2. Connect the four wires to the specific Communications device as shown in the accompanying figures.
3. If you are installing a 7845GSM or 7845i-GSM you must also install a jumper between terminals 2 and 3 on the
communications device.
4. Connect the device to the Internet via a cable/DSL modem and router or to an Intranet (LAN) via the appropriate Ethernet
connection, if applicable.
UL
UL
UL
UL
AlarmNet 7845GSM and 7845i-GSM modules have not been evaluated by UL.
* When available
7845GSM /
TB1
7845i-GSM
1
2
4
3
ECP (+) VOLTAGE INPUT
GND
4
5
5
Z1/Z2 OR DATA IN
Z3 OR DATA OUT
6
7845i-ENT / 7845i
TB 1
RED
(+) VOLTAGE INPUT
BLK
GND
GRN
DATA OUT
YEL
DATA IN
RED
BLK
YEL
GRN
4-WIRE CABLE (N4632-4)
Connecting AlarmNet 7845GSM / 7845i-GSM
4-WIRE CABLE (N4632-4)
Connecting AlarmNet 7845i-ENT/7845i/7847i-E*
CONTROL PANEL
LRR/IP COMMUNICATIONS PORT
GRN
DATA IN
BLK
GND
RED
+12 VDC
NC
YEL
DATA OUT
CONTROL PANEL
LRR/IP COMMUNICATIONS PORT
GRN
DATA IN
BLK
GND
RED
+12 VDC
NC
YEL
DATA OUT
- 10 -
LYNX
STANDARD
CAPACITY
BATTERY
LYNX
(OPTIONAL)
SUPER HIGH
REQUIRED FOR
CAPACITY
24-HR BACKUP
BATTERY
LYNX
STANDARD
CAPACITY
BATTERY
09012-018-V0
09012-019-V0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lynxr-2 series

Table of Contents