Diagnostic error codes

116
Hardware Maintenance Manual: Netfinity 4500R Type 8656
Diagnostic Panel LED
TEMP LED on (look at test
cases)
Note: In the following error codes, if XXX is 000, 195, or 197 do not replace a FRU.
The description for these error codes are:
000
The test passed.
195
The Esc key was pressed to abort the test.
197
This is a warning error and may not indicate a hardware failure.
For all error codes, replace/follow the FRU/Action indicated.
Error Code/Symptom
001-XXX-000
(Failed core
tests)
(Failed core
001-XXX-001
tests)
001-250-000
(Failed
System Board ECC)
001-250-001
(Failed
System Board ECC)
005-XXX-000
(Failed
Video test)
011-XXX-000
(Failed
COM1 Serial Port test)
011-XXX-001
COM2 Serial Port test)
1.
Ambient temperature must be within normal operating
specifications. See "Features and specifications" on page
3.
2.
Ensure fans are operating correctly.
3.
Examine System Error Log.
a.
System over recommended temperature
1)
Information LED Panel
2)
System Board
b.
DASD over recommended temperature (DASD LED
also on)
1)
Overheating hard drive
2)
DASD Backplane
3)
System Board
c.
System over recommended temperature for CPU X
(where X is CPU 1, 2,) (CPU LED also on)
1)
CPU X
d.
System Board over recommended temperature
4.
If the CPU LED on the diagnostics panel is also on, one of
the microprocessors has caused the error.
1.
System Board
1.
System Board
1.
System Board
1.
System Board
1.
System Board
1.
System Board
(Failed
1.
System Board
FRU/Action
FRU/Action

Advertisement

Table of Contents
loading

This manual is also suitable for:

8656 - eserver xseries 340Netfinity 4500r8656

Table of Contents