Diagnostic error codes

Refer to the following diagnostic error codes when using the diagnostic tests. See
"Diagnostics" on page 13 for the specific type for information about the Diagnostic
programs.
In the following index, X can represent any number.
Diagnostic Error Code
000-000-XXX
BIOS Test Passed
000-002-XXX
BIOS Timeout
000-024-XXX
BIOS Addressing test failure
000-025-XXX
BIOS Checksum Value error
000-026-XXX
FLASH data error
000-027-XXX
BIOS Configuration/Setup error
000-034-XXX
BIOS Buffer Allocation failure
000-035-XXX
BIOS Reset Condition detected
000-036-XXX
BIOS Register error
000-038-XXX
BIOS Extension failure
000-039-XXX
BIOS DMI data error
000-195-XXX
BIOS Test aborted by user
000-196-XXX
BIOS test halt, error threshold exceeded
FRU/Action
1.
No action
1.
Flash the system
2.
System board
1.
Flash the system
2.
System board
1.
Flash the system
2.
Boot block
3.
System board
1.
Flash the system
2.
Boot block
3.
System board
1.
Run Setup
2.
Flash the system
3.
Boot block
4.
System board
1.
Reboot the system
2.
Flash the system
3.
Run memory test
4.
System board
1.
Flash the system
2.
System board
1.
Flash the system
2.
Boot block
3.
System board
1.
Flash the system
2.
Adapter card
3.
System board
1.
Flash the system
2.
System board
1.
Information
2.
Re-start the test, if necessary
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file