11. Start the Configuration/Setup Utility program and set configuration parameters.

Replacing a fan assembly

The server comes with five replaceable fans.
Complete the following steps to replace the fan assembly. Use this procedure to
replace any fan in the server.
1. Read the safety information that begins on page iii and "Installation guidelines"
2. Turn off the server and all attached peripheral devices. Disconnect all power
3. Remove the server from the rack; then, remove the server cover (see
4. Determine which fan to replace by checking the LED at each fan; a lit LED
50
326m Type 7969: Hardware Maintenance Manual and Troubleshooting Guide
8. Put the PCI adapter shield back into place.
9. Reinstall the server cover, and connect the cables.
v Set the system date and time.
v Set the user (power-on) password.
v Reconfigure the server.
For for information, see the section about using the Configuration/Setup Utility
program in the User's Guide on the IBM Eserver Documentation CD.
on page 29.
cords; then, disconnect all external signal cables from the server.
"Removing the cover and bezel" on page 32).
Attention:
When you handle static-sensitive devices, take precautions to
avoid damage from static electricity. For information about handling these
devices, see "Handling static-sensitive devices" on page 30.
indicates the fan to replace.
Note: For more information about the LEDs, see the Hardware Maintenance
Manual and Troubleshooting Guide.