Table 1. Features and specifications
Microprocessor:
v AMD Opteron
processor
v 1 MB Level-2 cache
Note: Use the Configuration/Setup
Utility program to determine the type
and speed of the microprocessors.
Memory:
v Minimum: 1024 MB
v Maximum: 16 GB
v Type: PC3200 error correcting
code (ECC), double-data rate
(DDR) SDRAM, registered DIMMs
with Chipkill
memory protection
v Sizes: 512 MB, 1 GB, or 2 GB
DIMMS in pairs
v Four interleaved slots with
standard microprocessor
v Four additional interleaved slots
with optional microprocessor
Drives:
v CD: Slim IDE (standard only on
some models)
v Hard disk drives:
– Slim-high 3.5-inch drives,
hot-swap SCSI or
non-hot-swap Serial ATA
(SATA) (drive capacity and
speed vary with model)
– Maximum: Two
Expansion slots:
v Two, used in either of the
following configurations:
– One 133 MHz/64-bit PCI-X
(full-length) and one PCI
Express x8 (half-length)
– One PCI Express x8
(half-length) and one PCI
Express x8 (full length) with
purchase of PCI Express x8
riser card
v Supports 3.3 V or universal
adapters only
4
326m Type 7969: Hardware Maintenance Manual and Troubleshooting Guide
Video controller:
v ATI RN50b video controller on
system board
v Compatible with SVGA
v 16 MB DDR1 video memory
Power supply:
One 411 watt (115-230 V ac)
Size:
v Height: 43 mm (1.69 in.)
v Depth: 660 mm (25.98 in.)
v Width: 440 mm (17.32 in.)
v Weight: approximately 12.7 kg (28
lb) when fully configured
Integrated functions:
v Baseboard management controller
v One single-channel LSI Ultra320
SCSI controller
v Two Broadcom 10/100/1000
Ethernet controllers (dual-port
design) with Wake on LAN
support
v Four Universal Serial Bus (USB)
ports
v One serial port
v One video port
Note: The baseboard management
controller is also known as the
service processor.
Acoustical noise emissions:
v Declared sound power, idling: 6.5
bels
v Declared sound power, operating:
6.5 bels
Environment:
v Air temperature:
– Server on: 10°to 35°C (50.0° to
95.0°F). Altitude: 0 to 914 m
(2998.7 ft)
– Server on: 10° to 32°C (50.0° to
89.6°F). Altitude: 914 m (2998.7
ft) to 2133 m (6998.0 ft)
– Server off: 10° to 43°C (50.0° to
109.4°F). Maximum altitude:
2133 m (6998.0 ft)
v Humidity:
– Server on: 8% to 80%
– Server off: 8% to 80%
v Airflow rates:
– Minimum: 28 CFM
– Maximum: 47 CFM
Heat output:
Approximate heat output in British
thermal units (Btu) per hour for dual
multiprocessor configurations:
v Minimum configuration: 409 Btu (120
watts)
v Maximum configuration: 1366 Btu
(400 watts)
Electrical input:
v Sine-wave input (50-60 Hz) required
v Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
v Input voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
v Input kilovolt-amperes (kVA),
approximately:
– Minimum: 0.120 kVA
®
– Maximum: 0.400 kVA
Notes:
1. Power consumption and heat output
vary depending on the number and
type of optional features installed
and the power-management optional
features in use.
2. These levels were measured in
controlled acoustical environments
according to the procedures
specified by the American National
Standards Institute (ANSI) S12.10
and ISO 7779 and are reported in
accordance with ISO 9296. Actual
sound-pressure levels in a given
location might exceed the average
values stated because of room
reflections and other nearby noise
sources. The declared sound-power
levels indicate an upper limit, below
which a large number of computers
will operate.