Chapter 2
Messages and Recovery Procedures
Error Message %C7600_SSC400-3-SINGLE_SPA_MODE: Module will use only bay [dec]. Bay
[dec] is shut.
Error Message %C7600_SSC400-3-SSC_BAY_SHUT: Bay [dec] is shutdown because
7600-SSC-400 is in single-spa-mode
Error Message %C7600_SSC400-3-SW_ERROR: NULL
C7600_SSC400-7
Error Message %C7600_SSC400-7-DP_DISABLE: [chars] FPGA is forced disabled.
OL-11469-02
Explanation
The 7600-SSC-400 is in single-SPA mode.
This message is informational only. No action is required.
Recommended Action
The specified bay is shut down. In single-SPA mode, only one bay is active.
Explanation
Refer to the IPsec SPA documentation for information about single-SPA mode.
Recommended Action
A software error occurred.
Explanation
Copy the error message exactly as it appears on the console or in the system
Recommended Action
log. Research and attempt to resolve the error using the Output Interpreter
https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the
Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet
http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support
representative and provide the representative with the gathered information.
Explanation
This field-programmable gate array (FPGA) has been forced into a disabled state. This
is a debugging feature.
No action is required.
Recommended Action
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
C7600_SSC400 Messages
2-43
Need help?
Do you have a question about the III - Supervisor Engine III and is the answer not in the manual?