Chapter 2
Messages and Recovery Procedures
C7600_SIP200 Messages
This section contains SPA Interface Processor 200 (C7600_SIP200) messages.
C7600_SIP200-3
Error Message %C7600_SIP200-3-BADIFCTRL: Corrupted sip-200 information for interface
[chars] [[hex]]
Error Message %C7600_SIP200-3-SONET_CLOCK_FAILED: SPA Sonet clock has failed (status
= [hex])
Error Message %C7600_SIP200-3-SONET_CLOCK_RECOVERED: SPA Sonet clock has recovered
(status = [hex])
C7600_SIP200-4
Error Message %C7600_SIP200-4-MEM_MODULE_MISMATCH: Memory modules are not identical
C7600_SIP200_MP Messages
This section contains SIP 200 Multiprocessing (C7600_SIP200_MP) messages.
OL-11469-02
Explanation
The interface SIP 200 information is not valid. An internal software error has occurred.
Copy the error message exactly as it appears on the console or in the system
Recommended Action
log, collect the output of the show memory command on the line card, and contact your technical
support representative with the gathered information.
Explanation
The SPA SONET clock has failed. SPAs that rely on the SPA SONET clock for proper
operation, such as PoS and ATM, will be affected.
Recommended Action
If the SPA SONET clock does not recover, perform an OIR.
Explanation
SPA SONET clock has recovered.
No action is required.
Recommended Action
The memory modules do not have identical parameters. This condition might impact
Explanation
performance.
Recommended Action
Copy the error message exactly as it appears on the console or in the system
log, collect the output of show memory command on the line card, and contact your technical
support representative with the gathered information.
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
C7600_SIP200 Messages
2-27
Need help?
Do you have a question about the III - Supervisor Engine III and is the answer not in the manual?