C7600_SSC400-3

Error Message %C7600_SSC400-3-DCM_FAIL: [chars] FPGA module DCM Lock Failure,
status:[hex]
Error Message %C7600_SSC400-3-DP_COUNTERS: Failed to create DP counter process.
Error Message %C7600_SSC400-3-DP_ERROR: Bus Error initializing [chars] FPGA, addr:
[hex].
OL-11469-02
Explanation
One or more of the Digital Clock Managers (DCM) for the data path
field-programmable gate arrays (FPGAs) failed to lock. This indicates a hardware failure.
Copy the error message exactly as it appears on the console or in the system
Recommended Action
log. Research and attempt to resolve the error using the Output Interpreter
https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the
Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet
http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support
representative and provide the representative with the gathered information.
The system was unable to launch a process on bootup to monitor the counters of the data
Explanation
path field-programmable gate arrays (FPGAs).
Recommended Action
Copy the error message exactly as it appears on the console or in the system
log. Research and attempt to resolve the error using the Output Interpreter
https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the
Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet
http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support
representative and provide the representative with the gathered information.
This field-programmable gate array (FPGA) could not be initialized due to a bus error.
Explanation
This condition indicates a hardware failure, possibly due to a failed field-programmable device
(FPD) upgrade.
Enter the show hw-module slot fpd command. If this message recurs, copy the
Recommended Action
error message exactly as it appears on the console or in the system log. Research and attempt to
resolve the error using the Output Interpreter
https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the
Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance,
open a case with the Technical Assistance Center via the Internet
http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support
representative and provide the representative with the gathered information.