C6KPWR Messages
C6KPWR Messages
This section contains Catalyst 6500 series switch and Cisco 7600 series router power (C6KPWR)
messages.
C6KPWR-2
Error Message %C6KPWR-2-INSUFFICIENTPOWER: Powering down all linecards as there is
not enough power to operateall critical cards
Error Message %C6KPWR-2-MAJORPOWERALARM: In the absence of power supply 1, system
power usage exceeds allowed range of [chars]W. Power total will be reduced in [dec]
seconds
Error Message %C6KPWR-2-MAJORPOWERALARMRECOVER: System power usage has returned to
allowed operating range
Error Message %C6KPWR-2-MINORPOWERALARM: In the absence of power supply 1, system
power usage exceeds the recommended range of [chars]W
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
2-24
The switch was operating with two power supplies in combined mode. One of the power
Explanation
supplies has failed. Available power is insufficient to support all critical service modules. Critical
service modules include modules that support VPNs or IP security. If these critical modules fail,
security issues could arise; therefore, all modules have been powered down.
Replace the failed power supply.
Recommended Action
The power supply in slot 2 has exceeded its allowed range, causing a major power alarm.
Explanation
The range is specified in the error message.
Enter the show power command to determine the actual power usage. Insert a
Recommended Action
power supply in power supply slot 1, or power down some modules to reduce system power usage.
If downtime can be scheduled, move the power supply from slot 2 to slot 1. If this condition persists,
the environmental monitor will shut down some modules to prevent a complete power failure.
System power usage has returned to the permitted operating range. The scheduled
Explanation
shutdown is cancelled, and the system will continue operating.
No action is required.
Recommended Action
The power supply in slot 2 has exceeded its allowed range, causing a minor power
Explanation
alarm. The range is specified in the error message. Selected modules will be shut down to prevent a
complete power failure.
Enter the show power command to determine the actual power usage. Insert a
Recommended Action
power supply in power supply slot 1, or power down some modules to reduce system power usage.
If downtime can be scheduled, move the power supply from slot 2 to slot 1.
Chapter 2
Messages and Recovery Procedures
OL-11469-02
Need help?