Ref. #
Reporting Code
[00040309] Waterflow Trouble/Rest.
[00040309] Fire Test Begin
[00040309] Fire Test End
[00040309] Fire Bypass/Unbypass
[00040310] User Closings
[00040311] Closing 129-1500
[00040311] Special Closing
[00040311] Partial Closing
[00040311] Automatic (Scheduled) Clos-
ing
[00040311] Auto Arm Cancellation
[00040312] Partition Closing
[00040313] User Openings
[00040314] Opening 129-1500
[00040314] Special Opening
[00040314] Automatic (Scheduled)
Opening
[00040314] Door Shunt
[00040315] Partition Opening
[00040316] Battery Trouble/Rest.
[00040316] AC Line Trouble/Rest.
[00040316] Panel Bell Trouble/Rest.
[00040316] Panel Auxiliary Trouble/Rest.
[00040316] Combus Trouble/Rest.
[00040316] TLM Failure/Rest.
[00040316] TLM Line2 Failure/Rest.
[00040316] FTC Restoral
[00040316] Buffer Near Full
[00040316] User System Test
[00040316] Periodic Test
[00040316] Periodic Test Tbl
[00040316] LINKS Test
[00040316] Ground Fault/Rest.
[00040316] DLS Lead In
[00040316] DLS Lead Out
[00040316] Installer Lead In
[00040316] Installer Lead Out
70
Code Sent When...
waterflow zone has trouble (open) condition
(PC4701 only)
fire inspector's test start & fire drill test begins
fire inspector's test end & fire drill test ends
fire zone bypassed/unbypassed
partition armed (user 001-128 indicated)
user code # 129-1500 used to arm partition
one or more zones intentionally bypassed
when partition armed
auto arming according to schedule
auto arm cancelled
partition armed (partition number indicated)
partition disarmed (user 001-128 indicated)
user code # 129-1500 used to disarm partition
disarm with WLS909, Second Master code,
keyswitch, downloading or guard code
auto disarming according to schedule
PC4820 zone shunted while armed
partition disarmed (partition number indi-
cated)
PC4020 battery is low
AC power to control panel is disconnected or
interrupted
open circuit detected across bell terminals
aux voltage supply trouble
control panel loses communications with con-
nected module(s) or has low power
telephone line 1 monitoring trouble (sent via
LINKS. Do not program if LINKS not used)
telephone line 2 monitoring trouble (sent via
LINKS. Do not program if LINKS not used)
control panel has restored communications to
central station (after TLM Fail)
printer not used or off-line for 450 events
[*][6] bell/communications test
periodic test transmission
periodic test transmission trouble
LINKS test transmission
EGND connection detects a ground fault
DLS Call Back feature only: downloading ses-
sion start
DLS Call Back feature only:
downloading session complete
Installer code has been entered
Installer's programming complete
** PPP = partition number; UUU = user number (user 1000 to 1500 = 999); ZZZ = zone number
Dialer
Contact
Direction*
A/R
A/R
A/R
A/R
O/C
O/C
O/C
O/C
(4/5) 56
O/C
O/C
O/C
O/C
O/C
O/C
O/C
O/C
O/C
O
O
O
O
O
O
O
O
O
(3) None
O
O
O
O
O
O
O
O
O
* A/R = alarms/restorals; O/C = openings/closings; O = other
SIA Auto Rep
ID
Codes**
(3) 73
ST-998/SJ-998
(6) A4
FI-000
(6) A4
FK-000
(5) 71
FB-ZZZ/FU-ZZZ
(4) A2
CL-UUU
(4) A2
CL-UUU
(4) A2
CL-000
CW-000
(4) A3
CA-000
(4) A5
CE-000
(4) AA
CG-PPP
(4) A2
OP-UUU
(4) A2
OP-UUU
(4) A2
OP-000
(4) A3
OA-000
(5) 76
DG-222
(4) AA
OG-PPP
(3) A2
YT-000/YR-000
(3) A1
AT-000/AR-000
(3) 21
YA-000/YH-000
(3) AA
YP-000/YQ-000
(3) 33
UT-000/UJ-000
(3) 51
LT-001/LR-001
(3) 52
LT-002/LR-002
(3) 54
YK-000
JL-000
(6) A1
RX-000
(6) A2
RP-000
(6) A7
RP-001
(6) A3
TX-000
(3) 1A
US-000/UR-000
(4) 11
RB-000
(4) 12
RS-000
(4) 58
LB-000
(4) 58
LS-000

Hide quick links: