DSC PC4020 Installation Manual page 43

V3.5 dls2002 or higher
Hide thumbs Also See for PC4020:
Table of Contents

Advertisement

NOTE: This option should be enabled when using global
zones.
• PC ID
PC ID
PC ID: If enabled, the panel will identify all manually
PC ID
bypassed zones when the partition is armed. The partial
closing reporting code must be programmed for this fea-
ture to work.
• If disabled, the panel will only send a partial closing
reporting code to tell the central station that zones were
bypassed when the partition was armed (default=No).
• PC on Auto Arm
PC on Auto Arm: If enabled, the panel will send the
PC on Auto Arm
PC on Auto Arm
partial closing reporting code to the central station
when a zone is force armed during auto-arming. If dis-
abled, no partial closing reporting code will be sent
(default=Yes).
• PC ID Restores
PC ID Restores: If enabled, the zone restoral reporting
PC ID Restores
PC ID Restores
codes will be transmitted instead of the zone alarm
reporting codes to identify the manually bypassed and
force armed zones upon auto-arming. If disabled, the
zone alarm reporting codes will be sent (default=No).
• TLM Enabled
TLM Enabled: If enabled, the system will test for tele-
TLM Enabled
TLM Enabled
phone line faults. The keypads will indicate any faults
detected (default=Yes).
• TLM Aud Bell
TLM Aud Bell
TLM Aud Bell: If enabled, all bells will be audible when
TLM Aud Bell
a telephone line trouble is present and the partition is
armed (default=Yes).
• FTC Aud Bell
FTC Aud Bell
FTC Aud Bell: If enabled, a Failure To Communicate
FTC Aud Bell
trouble will cause the bell outputs to activate. If dis-
abled, only the keypads will annunciate the trouble
(default=No).
• TLM + Alarm Aud
TLM + Alarm Aud
TLM + Alarm Aud
TLM + Alarm Aud: This option will determine whether
the burg bell outputs will activate when a Transmission
Line Monitoring trouble and an alarm occur simulta-
neously. If enabled, the bells for the armed partition will
sound.
• Ringback
Ringback: If enabled, the partition keypad will beep 10
Ringback
Ringback
times when a successful communication of a closing to
the central station occurs (default=No).
NOTE: If communications are being sent to more than one
telephone number, communications to all numbers will
produce a ringback.
• Ringback Sqwk
Ringback Sqwk: If enabled, the partition keypad and the
Ringback Sqwk
Ringback Sqwk
partition bell outputs (Fire/Burg, Inv Fire/Burg, Burg
and Invert Burg) will squawk when a successful com-
munication of a closing to the central station occurs
(default=No).
NOTE: The Ringback option must be enabled in order for
this feature to function.
• Periodic Test
Periodic Test
Periodic Test: If enabled, the panel will send a test trans-
Periodic Test
mission to the central station (default=No).
If this feature is enabled and a PC4701 module is
enrolled on the system, the panel will alternate sending
the periodic test transmission between Line 1 and Line 2
of the PC4701 so that both communication paths are
tested.
• Europe Dial
Europe Dial: If enabled, the contact closure to the tele-
Europe Dial
Europe Dial
phone line is made in a 67/33 make/break ratio. This is
the European standard method of dialing (default=No).
NOTE: Do not enable this option for North American instal-
lations.
• Default Dial
Default Dial: With this option enabled, if panel's first
Default Dial
Default Dial
attempt to call the central station fails, it will dial on
every subsequent attempt regardless of the presence of
a dial tone. When disabled, if a 'D' for dial tone search
precedes the telephone number, the panel will not dial if
dial tone is not present. See 12.1 'Telephone Numbers'
for programming the telephone numbers with dial tone
search (default=Yes).
• Ph 1-2 Backup
Ph 1-2 Backup: If enabled, the panel will attempt to
Ph 1-2 Backup
Ph 1-2 Backup
report to the second telephone number if it is unable to
communicate using the first telephone number. The
panel will attempt to call for the number of times pro-
C o m m u n i c a t i o n s
grammed as the Maximum Number of Dialing
Attempts. When used as a backup number, the dialer
direction options for the second telephone number
should be disabled (default=No).
• Ph 1-3 Backup
Ph 1-3 Backup: This option is similar to 'Ph 1-2 Backup'
Ph 1-3 Backup
Ph 1-3 Backup
except that the panel will backup to the third telephone
number instead of the second (default=No).
NOTE: If the 'Ph 1-2 Backup' option is also enabled, the
reporting code will be sent to both the second and third
telephone numbers if the panel is unable to communicate
using the first number.
• Ph 2-3 Backup
Ph 2-3 Backup
Ph 2-3 Backup: This option is similar to 'Ph 1-2 Backup'
Ph 2-3 Backup
except that the panel will attempt to report to the third
telephone number if it is unable to communicate using
the second telephone number (default=No).
NOTE: If the 'Ph 1-2 Backup' option is also enabled, the
reporting code will be sent to the second telephone num-
ber if the panel is unable to communicate using the first
number. If the panel also fails when attempting to call the
second telephone number, the panel will send the report-
ing code to the third number.
• Busy Tone Det.
Busy Tone Det.
Busy Tone Det.: If enabled, when a busy tone is detected
Busy Tone Det.
for four seconds, the panel will hang-up and wait for
the amount of time programmed as the Busy Tone
Delay before attempting to redial. If disabled, the panel
will not search for busy tone when dialing the telephone
number (default=No).
NOTE: This feature must not be used with the LINKS1000.
• 1300 Hz ID
1300 Hz ID: If enabled, the panel emits a 1300Hz identi-
1300 Hz ID
1300 Hz ID
fication tone from the time it dials to the time it hears
the handshake from the receiver. If disabled, no identifi-
cation tone is emitted (default=No).
NOTE: This option should not be used with Pager 2, Pager 3
or Contact ID formats. This feature should not be used in
North America.
• Alternate Dial
Alternate Dial: If enabled, the panel will alternate
Alternate Dial
Alternate Dial
between the first and second telephone numbers when
attempting to call the central station, regardless of the
dialer direction settings. If disabled, the panel will fol-
low the programmed backup dialing procedure
(default=No).
• SIA 1 Account #
SIA 1 Account #: See 12.6 'Communicator Formats' for
SIA 1 Account #
SIA 1 Account #
information.
• Auto Report SIA
Auto Report SIA: See 12.6 'Communicator Formats' for
Auto Report SIA
Auto Report SIA
information.
• Test Tx in Min
Test Tx in Min: If enabled, the test transmission timer
Test Tx in Min
Test Tx in Min
will be in minutes. If disabled, it will be in days. See 10.8
'Test Transmissions' (default = No).
• Tx Delay in Min
Tx Delay in Min
Tx Delay in Min: If enabled, the transmission delay will
Tx Delay in Min
be in minutes. If disabled, it will be in seconds. See 10.9
'Transmission Delay' (default = No).
• 2nd Line Flash
2nd Line Flash: If enabled, the panel will use the stan-
2nd Line Flash
2nd Line Flash
dard dialing routing with the following addition. If the
panel doesn't detect a dial tone during the first five sec-
onds, the panel will flash the line (hang up and pick up
again) for 90ms. The panel will then search for a dial
tone on the virtual line (default = No).
NOTE: This option is for use in Sweden only. Do not enable
in North America. If this and the LINKS1000 are enabled,
the LINKS dialing procedure will be slightly different. The
panel will backup to the LINKS on the third attempt.
• 6 digit Acct
6 digit Acct
6 digit Acct: If enabled, the system and partition account
6 digit Acct
numbers will be six digits for the SIA format. If dis-
abled, the account numbers will be four digits
(default=No).
• T-Link Enabled:
T-Link Enabled: This option must be set to [N] for a UL
T-Link Enabled:
T-Link Enabled:
Listed system. If enabled, a communications link
between this product and a receiver, DLS, computer or
other devices on a LAN/WAN will be used.
NOTE: A T-Link module must be connected to the PC-Link
connector on the panel.
P r o g r a m m i n g
39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maxsys pc4020cfMaxsys pc4020

Table of Contents