Bringing Up The System For The First Time - Cisco SFS-7012 - SFS InfiniBand Server Switch 7012 Hardware User's Manual

Server switch
Hide thumbs Also See for SFS-7012 - SFS InfiniBand Server Switch 7012:
Table of Contents

Advertisement

Chapter
When handling IB connectors, make certain to remove the connectors by pulling on the center of the
Note
lanyard only as shown in
of the lanyard will prevent the latch/unlatch operation from occurring, and could damage or break the
lanyard.
Figure 2-13 4X IB Cable Connector
Connecting Power
Provide strain relief for the power cable(s) by feeding them into the heyclips on the lower rail
Step 1
assemblies.
Note
Be certain that the power cords are firmly seated into the SFS 7012 AC power inlets. Depending upon
the purchased configuration, refer to
If necessary, replace the faceplates over the switch fans.
Step 2
Connect the power cables to an AC power outlet.
Step 3
When the SFS 7012 switch is plugged into an AC power outlet:
Step 4
a.
b.
c.
The switch, power supply, and fan LEDs light up.
Step 5

Bringing Up the System For the First Time

Start-up Procedures
Power up the SFS 7012.
Step 1
Step 2
From its flash image on the CMU spine module, the switch begins its boot process.
OL-8787-04
Figure 2-13
The system powers up.
The fans start.
The system performs a power-on self test (POST).
below. Pulling abruptly on the lanyard, or pulling on only one side
Figure 2-12
for which AC power inlet to use.
Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
29